Team:Oxford/Protein Based Experiments

Future Protein-Based System Experiments

Introduction

In our project, the central sfGFP-dark quencher part has been shown to have repressed fluorescence which is relieved on cleavage by TEV, and this fluorescence is unaffected by the presence of the TorA leader sequence, spycatcher and His tag. This represents the first design built test cycle, proving the concept of relieved repression at this point, and as will be seen, this will be used throughout our suggestions for future experiments. We have also designed the parts that would be used to target proteins to the membranes, and will explain the future experiments to test these.

DBT Cycle 1 - Membrane Insertion and OMV Packing Efficiency

Next DBT- design, build and test membrane insertion efficiency, and the packing efficiency into the OMV. Express the parts BBa_K2450401 and BBa_K2450451, which have SpyTag at the N terminal and in the middle of the protein respectively. Localisation of the fluorescence of these parts should be seen in the outer membrane, which can be performed by microscopy. Once it is confirmed that both these parts can be expressed in the membrane, the sfGFP should be removed by PCR, and subsequent experiments carried out in the absence of the fluorophore to avoid interference with other fluorescence experiments. The SpyCatcher-sfGFP part (with the dark quencher removed during PCR) should then be expressed in the same E. coli strains. These will then be transported into the OMVs which can be extracted by ultracentrifugation using the protocol shown here. The fluorescence of these OMVs can be compared, and the highest fluorescence will be the most efficient at targeting protein to the OMVs. This targeting protein can then be used in all subsequent experiments.

DBT Cycle 2 - OMV Lysis Method

After identifying the most efficient targeting protein, it is then possible to start assaying OMV lysis. We have proposed using a detergent, such TritonX or some other ‘soft’ detergent. The detergent should be able to be added in a powdered form, should not denature proteins, and should be cheap. It may be that future teams would like to test other methods, such as increase in temperature or sonication, which are tested in the same way. In assaying the OMVs, TEV protease should be added first and left, to ensure no fluorescence change occurs and that the OMVs are intact. If this is not the case, then the TEV protease + OMV mixture should be left until the fluorescence plateaus, and this taken as the new zero. The method being assayed should then be used (e.g. adding the detergent) and the fluorescence should increase as the OMVs are lysed and the TEV protease gains access to the SpyCatcher-sfGFP-TEV cleavage site-dark quencher. This assay has the advantage that if the lysis technique begins to lyse proteins, this will be seen as a decrease in fluorescence, and can be observed by its self by lysing the OMVs in the absence of TEV protease.

DBT Cycle 3 - Standardisation of TEV Cleavage

The next DBT cycle should be standardisation of TEV cleavage of the SpyCatcher-sfGFP-TEV protease cleavage site-dark quencher part (BBa_K2450501) in OMVs. OMVs containing this part should be generated as in the OMV lysis assays above. The OMVs should be lysed using the chosen lysis method, left for a while, and the TEV protease added after incubation, to ensure a standard response by the TEV protease. Then, the Michaelis-Menton curves at several concentrations of TEV should be produced. The timepoint at which there is the most separation between the curves should be selected as the timepoint to measure the fluorescence of future cleavage experiments. A standard curve should be produced against known concentrations of TEV at this timepoint T. This will allow the future quantification of the amount of TEV produced. It should be noted that the standardisation of fluorescence levels of GFP as is being attempted by the interlab challenge would be particularly helpful, as it would allow different groups to share and directly compare standard curves and data.

DBT Cycle 4 - Testing TEV Protease Output

Once the fluorescence response of the quenched fluorescence OMVs has been standardised against known concentrations of TEV the feedback loop can be tested. For a full explanation of how the feedback loop works, see the project design page, OMV section. For this, the two halves of the split TEV should be loaded into outer membrane vesicles. Each should have a fluorophore, between which FRET can occur. In this way, if a problem occurs, it can be determined as to whether or not dimerization is not occurring or the subsequent complex is not active. It also serves to demonstrate colocalization to the outer membrane, and presence in the OMVs. On lysis of the OMVs, the system should then be incubated to see if it is able to activate its self. Over multiple experiments the probability of a false positive should be able to be deduced. After incubation, a known concentration of active TEV should be added. If the split-TEV feedback loop is activated, the fluorescence will increase at a greater rate, and an exponentially growing rate as more active TEV is produced.