Difference between revisions of "Team:UCLouvain/Badge"

Line 18: Line 18:
 
</div>
 
</div>
  
<p>The design of the badge was an important part of our work. It must be small, practical and bio-secure, preventing our bacteria from escaping into the environment. Because our badge is specifically made to be used outside the lab, the biosecurity part needed particulars attentions. To answer these specifications, we decided to make it as an assembly of three separated pieces, all of which can be 3D printed. Some parts are also safely reusable, so you don’t have to replace the entire badge when it is used.</p>
+
<p>The design of the badge has been a significant part of our work. It must be small, practical and bio-secure, preventing our bacteria from escaping into the environment. As our badge is specifically made to be used outside the lab, the biosecurity aspect needed careful attention. To respect these specifications, we decided to set it up as an assembly of three separate pieces, all of which can be 3D printed. Some parts are also safely reusable, so you don’t have to replace the entire badge when it is used.</p>
 
</div>
 
</div>
 
</div>
 
</div>
Line 31: Line 31:
 
<div class="row" style="margin-bottom: 40px;">
 
<div class="row" style="margin-bottom: 40px;">
 
<div class="col-md-6">
 
<div class="col-md-6">
<p>The second part is the heart of our system, we call it the capsule. It’s the piece that holds the medium containing our UV sensitives bacteria. For this matter, it is completely sealed, except from a small hole left on the side which allows us to fill it with medium and bacteria. This hole will also be used to ensure the biosafety of our badge, in cooperation with the last part. Regarding the top of the capsule, it is covered with a transparent polymer, that lets both visible and UV light pass through. There are also two smalls teeth on the bottom, these fit into the support grooves to secure the capsule in place. You can finally find a small bump on top of the hole, it will be used to secure this piece into the support using the final part.</p>
+
<p>The second part is the heart of our system, we call it the capsule. It’s the piece that holds the medium containing our UV sensitives bacteria. Therefore, it is completely sealed, except for a small hole left on the side which allows us to fill it with medium and bacteria. This hole will also be used to ensure the biosafety of our badge, in cooperation with the last part. Regarding the top of the capsule, it is covered with a transparent polymer, that lets both visible and UV light pass through. There are also two smalls teeth on the bottom which fit into the support grooves to secure the capsule in place. You can finally find a small bump on top of the hole which will be used to secure this piece into the support using the final part.</p>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
Line 42: Line 42:
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
<p>Last but not least, the next part is called the safety ring. It will act as one of our biosecurity features. It’s a hollow cylinder that contains bleach, connected to the outside only by a small hole on the interior. Similarly to the hole in the capsule, this one serves as an opening to fill the ring and as the second cooperating part regarding the biosafety mechanism. You can also find a little bump on top of the ring, which is hanging out on the inside of it. This ring is placed around the capsule, which is already inside the support. The ring needs to be able to turn freely around the capsule, only limited by the small bumps.</p>
+
<p>Last but not least, the next part is called the safety ring. It will act as one of our biosecurity features. It’s a hollow cylinder that contains bleach, connected to the outside only by a small hole on the inside. Similarly to the hole in the capsule, this one serves as an opening to fill the ring and as the second cooperating part regarding the biosafety mechanism. You can also find a little bump on top of the ring, which is hanging inside. This ring is placed around the capsule, which is already inside the support. The ring needs to be able to turn freely around the capsule, only limited by the small bumps.</p>
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="row" style="margin-bottom: 40px;">
 
<div class="row" style="margin-bottom: 40px;">
 
<div class="col-md-12">
 
<div class="col-md-12">
<p>A seal is needed in-between the last two parts to ensure that there are no leaks. Once the three parts are assembled and filled with their respective liquid, the badge is finished and ready to be used.</p>
+
<p>A seal is needed in-between the last two parts to ensure that there are no leaks. Once the three parts are assembled and filled with their respective liquids, the badge is finished and ready to be used.</p>
  
 
<img src="https://static.igem.org/mediawiki/2017/2/24/Badge_Assemblage.png" class="in_text_img" style="width: 500px;">
 
<img src="https://static.igem.org/mediawiki/2017/2/24/Badge_Assemblage.png" class="in_text_img" style="width: 500px;">
  
<p>In order to secure the capsule into the support, you need to first put the capsule into the support, by matching the teeth with the grooves. Then you add the safety ring around the capsule, making sure that the holes are not facing each other. Finally, you turn the safety ring clock wise. When the bumps on the capsule and on the ring make contact, continuing turning will force the capsule to turn with the ring. It will secure it inside the support, thanks to the groove on the bottom of it. The badge is now assembled and ready to be used as a UV sensor.</p>
+
<p>In order to secure the capsule into the support, you need to put the capsule into the support first, by matching the teeth with the grooves. Then you add the safety ring around the capsule, making sure that the holes are not facing each other. Finally, you turn the safety ring clock wise. When the bumps on the capsule and on the ring come into contact, continuing turning will force the capsule to turn with the ring. It will be secured inside the support, thanks to the groove at the bottom. The badge is now assembled and ready to be used as a UV sensor.</p>
  
<p>Once the capsule has been used, you need to change it. To do so, simply turn the ring counter clockwise. Once the small bumps are in contact, continue to turn. The small capsule will turn too, making it able to leave the support with the ring. When the small bumps make contact, the hole into the capsule and into the safety ring will perfectly match. This means that the solution of each compartment will be mixed together. The bleach will kill all the bacteria, leaving nothing but dead cell fragments and aggregates of proteins. Using this mechanism, we ensure that every time a capsule is replaced, the bacteria inside the old capsule are killed. The capsule can then be trashed safely or recovered to replenish it with bacteria.</p>
+
<p>Once the capsule has been used, it needs replacing. To do so, simply turn the ring anticlockwise. Once the small bumps are in contact, keep turning. The small capsule will turn too, enabling it to leave the support with the ring. When the small bumps get in touch, both hole in the capsule and in the safety ring will perfectly match. This means that the solution of each compartment will be mixed together. The bleach will kill all the bacteria, leaving nothing but dead cell fragments and protein aggregate. Using this mechanism, we ensure that every time a capsule is replaced, the bacteria inside the old capsule are killed. The capsule can then be trashed safely or recovered to replenish it with bacteria.</p>
  
 
<p>Our prototype was printed using a MakerBot Replicator 2X Experimental 3D Printer and with polylactic acid (PLA) as a polymer. The top of the capsule was not printed due to some technical limitation. Nevertheless, poly(methyl methacrylate) (PMMA) could be used as it allows light transmittance in the visible range and at our desired wavelength (365 nm)[1].</p>
 
<p>Our prototype was printed using a MakerBot Replicator 2X Experimental 3D Printer and with polylactic acid (PLA) as a polymer. The top of the capsule was not printed due to some technical limitation. Nevertheless, poly(methyl methacrylate) (PMMA) could be used as it allows light transmittance in the visible range and at our desired wavelength (365 nm)[1].</p>
  
<p>1) Ahmed, R. M. 2009. “Optical Study on Poly(methyl methacrylate)/Poly(vinyl Acetate) Blends.” Research article. International Journal of Photoenergy. 2009</p>
+
<p>[1]Ahmed, R. M. 2009. “Optical Study on Poly(methyl methacrylate)/Poly(vinyl Acetate) Blends.” Research article. International Journal of Photoenergy. 2009</p>
  
 
<img src="https://static.igem.org/mediawiki/2017/a/a7/UCLOUVAIN_badge_exterieur.jpeg" class="in_text_img" style="width: 500px;">
 
<img src="https://static.igem.org/mediawiki/2017/a/a7/UCLOUVAIN_badge_exterieur.jpeg" class="in_text_img" style="width: 500px;">

Revision as of 23:36, 30 October 2017

iGEM UCLouvain Team iGEM UCLouvain Team

Our Project
The badge
Badge

The design of the badge has been a significant part of our work. It must be small, practical and bio-secure, preventing our bacteria from escaping into the environment. As our badge is specifically made to be used outside the lab, the biosecurity aspect needed careful attention. To respect these specifications, we decided to set it up as an assembly of three separate pieces, all of which can be 3D printed. Some parts are also safely reusable, so you don’t have to replace the entire badge when it is used.

The first one is the support, that can be attached to a bracelet by simply pulling it through the gaps on both edges. This part will never get in contact with the bacteria and is thus reusable. The middle part of the support contains a hole, allowing the second part of the badge to come in and to be secured, thanks to the groove on the side and on the bottom.

The second part is the heart of our system, we call it the capsule. It’s the piece that holds the medium containing our UV sensitives bacteria. Therefore, it is completely sealed, except for a small hole left on the side which allows us to fill it with medium and bacteria. This hole will also be used to ensure the biosafety of our badge, in cooperation with the last part. Regarding the top of the capsule, it is covered with a transparent polymer, that lets both visible and UV light pass through. There are also two smalls teeth on the bottom which fit into the support grooves to secure the capsule in place. You can finally find a small bump on top of the hole which will be used to secure this piece into the support using the final part.

Last but not least, the next part is called the safety ring. It will act as one of our biosecurity features. It’s a hollow cylinder that contains bleach, connected to the outside only by a small hole on the inside. Similarly to the hole in the capsule, this one serves as an opening to fill the ring and as the second cooperating part regarding the biosafety mechanism. You can also find a little bump on top of the ring, which is hanging inside. This ring is placed around the capsule, which is already inside the support. The ring needs to be able to turn freely around the capsule, only limited by the small bumps.

A seal is needed in-between the last two parts to ensure that there are no leaks. Once the three parts are assembled and filled with their respective liquids, the badge is finished and ready to be used.

In order to secure the capsule into the support, you need to put the capsule into the support first, by matching the teeth with the grooves. Then you add the safety ring around the capsule, making sure that the holes are not facing each other. Finally, you turn the safety ring clock wise. When the bumps on the capsule and on the ring come into contact, continuing turning will force the capsule to turn with the ring. It will be secured inside the support, thanks to the groove at the bottom. The badge is now assembled and ready to be used as a UV sensor.

Once the capsule has been used, it needs replacing. To do so, simply turn the ring anticlockwise. Once the small bumps are in contact, keep turning. The small capsule will turn too, enabling it to leave the support with the ring. When the small bumps get in touch, both hole in the capsule and in the safety ring will perfectly match. This means that the solution of each compartment will be mixed together. The bleach will kill all the bacteria, leaving nothing but dead cell fragments and protein aggregate. Using this mechanism, we ensure that every time a capsule is replaced, the bacteria inside the old capsule are killed. The capsule can then be trashed safely or recovered to replenish it with bacteria.

Our prototype was printed using a MakerBot Replicator 2X Experimental 3D Printer and with polylactic acid (PLA) as a polymer. The top of the capsule was not printed due to some technical limitation. Nevertheless, poly(methyl methacrylate) (PMMA) could be used as it allows light transmittance in the visible range and at our desired wavelength (365 nm)[1].

[1]Ahmed, R. M. 2009. “Optical Study on Poly(methyl methacrylate)/Poly(vinyl Acetate) Blends.” Research article. International Journal of Photoenergy. 2009

you think we're cool? so are our sponsors!
  • UCL
  • Fédération Wallonie Bruxelles
  • Fondation Louvain
  • Imperial College
  • Agilent Technologies
  • AGL
  • ISV
  • UCL faculté des Sciences