Difference between revisions of "Team:Newcastle/Results"

Line 985: Line 985:
 
           Ten projects were unable to be reviewed because their wiki was broken. Of the remaining 111 projects, 18 projects were deemed not eligible for further analysis. This was either due to a lack of information regarding biosensor mechanism provided by the team or their project was irrelevant. 3 projects were excluded as the sensing component of their project was unchanged from a previous project, to prevent the overrepresentation of biosensors in our database. Therefore, a total of 93 biosensors were used for analysis in our systematic review. (MIGHT PUT ALL THIS INTO A FIGURE) The systematic review revealed that all biosensors could be split into four components:  
 
           Ten projects were unable to be reviewed because their wiki was broken. Of the remaining 111 projects, 18 projects were deemed not eligible for further analysis. This was either due to a lack of information regarding biosensor mechanism provided by the team or their project was irrelevant. 3 projects were excluded as the sensing component of their project was unchanged from a previous project, to prevent the overrepresentation of biosensors in our database. Therefore, a total of 93 biosensors were used for analysis in our systematic review. (MIGHT PUT ALL THIS INTO A FIGURE) The systematic review revealed that all biosensors could be split into four components:  
 
</br>
 
</br>
       <b> Detector: </b>The part responsible for detection of the target molecules. For example, riboswitches and transcription factors. </br>
+
       <b> 1)Detector: </b>The part responsible for detection of the target molecules. For example, riboswitches and transcription factors. </br>
       <b> Processing: </b>Adds downstream processing to a signal, which enables response turning. For example, logic gates, signal amplification and sensitivity tuning. </br>
+
       <b> 2)Processing: </b>Adds downstream processing to a signal, which enables response turning. For example, logic gates, signal amplification and sensitivity tuning. </br>
       <b>Reporter or output: </b>Produces a response to the target. For example, fluorescent proteins and beta-galactosidase. Additionally, some biosensors may produce outputs which interact with the target molecule once it has been sensed, such as the production of degradation enzymes in bioremediation projects. We have termed these outputs as “effectors”</br>
+
       <b>3)Reporter or output: </b>Produces a response to the target. For example, fluorescent proteins and beta-galactosidase. Additionally, some biosensors may produce outputs which interact with the target molecule once it has been sensed, such as the production of degradation enzymes in bioremediation projects. We have termed these outputs as “effectors”</br>
<b> Adaptors: </b> Adaptors – If the molecule is hard to detect, adaptor components can be placed before the detector unit, to convert the target molecules to something able to be sensed by the detector component. For example, for target that degrades into an easily detectable molecule, a biochemical conversion adaptor could be placed before the detector component which enzymatically degrades the target molecule into the molecule detected by the detector module.  
+
<b>4)Adaptors: </b> Adaptors – If the molecule is hard to detect, adaptor components can be placed before the detector unit, to convert the target molecules to something able to be sensed by the detector component. For example, for target that degrades into an easily detectable molecule, a biochemical conversion adaptor could be placed before the detector component which enzymatically degrades the target molecule into the molecule detected by the detector module.  
 
           </br>
 
           </br>
 +
<img src="https://static.igem.org/mediawiki/2017/6/6e/Igembiosensors_graph.png" style="margin: 2%; max-width: 70%">
 +
<p>
 +
<b>Figure 2: Frequency of projects based on biosensors development in iGEM. </b></p>
 +
         
 +
<img src="https://static.igem.org/mediawiki/2017/2/25/Igembiosensors_table.png" style="margin: 2%; max-width: 70%">
 +
<p>
 +
<b>Table 1: Percentages of biosensors components used in iGEM. </b></p>
  
          picture piiiicture
 
 
           </br></br>
 
           </br></br>
 
           We propose that splitting these modular biosensor components into different cells, as shown below, and co-culturing the cells together, will greatly reduce the complexity of biosensor circuit development. </p>
 
           We propose that splitting these modular biosensor components into different cells, as shown below, and co-culturing the cells together, will greatly reduce the complexity of biosensor circuit development. </p>

Revision as of 12:58, 29 October 2017

spacefill

Our Experimental Results

Biochemical Adaptor

Target

Detector Modules

Multicellular Framework Testing

C12 HSL: Connector 1

Processor Modules

Framework in Cell Free Protein Synthesis Systems

C4 HSL: Connector 2

Reporter Modules



Looking for Interlab Study
related results? Click below!