<p class="legend"><strong>Figure 8:</strong> Pellets collected after overnight co-cultures of Arsenic detector (<a href="http://parts.igem.org/Part:BBa_K2205022">BBa_K2205022</a>) + processor (<a href="http://parts.igem.org/Part:BBa_K2205012">BBa_K2205012</a>) + sfGFP reporter (<a href="http://parts.igem.org/Part:BBa_K2205015">BBa_K2205015</a>) in ratio 1:1:13, with different concentrations of Arsenic (0ppb, 10ppb, 50ppb, 100ppb).</p>
 
<p class="legend"><strong>Figure 8:</strong> Pellets collected after overnight co-cultures of Arsenic detector (<a href="http://parts.igem.org/Part:BBa_K2205022">BBa_K2205022</a>) + processor (<a href="http://parts.igem.org/Part:BBa_K2205012">BBa_K2205012</a>) + sfGFP reporter (<a href="http://parts.igem.org/Part:BBa_K2205015">BBa_K2205015</a>) in ratio 1:1:13, with different concentrations of Arsenic (0ppb, 10ppb, 50ppb, 100ppb).</p>
</div>
+
</div></br>
 
+
<p>The preliminary qualitative assay above shows that there is no significant difference among the samples when inoculated with Arsenic in different concentrations and the controls (no Arsenic). Optimisation of the Arsenic detection into the Sensynova framework is required. </p>
  
 
</td>
 
</td>
Line 574: Line 574:
 
</table>
 
</table>
 
           <h2 style="font-family: Rubik; text-align: left; margin-top: 1%"> Conclusions and Future Work </h2>
 
           <h2 style="font-family: Rubik; text-align: left; margin-top: 1%"> Conclusions and Future Work </h2>
           <p>The preliminary qualitative assay above shows that there is no significant difference among the samples when inoculated with Arsenic in different concentration and the controls (with no Arsenic).</p>
+
           <p>The results demonstrate that further characterisation needs to be conducted in order to optimise the Arsenic detector variant in the Sensynova platform. However, due to time constraints, we were not able to do so.</p>
  
 
           <h2 style="font-family: Rubik; text-align: left; margin-top: 1%"> References </h2>
 
           <h2 style="font-family: Rubik; text-align: left; margin-top: 1%"> References </h2>

Revision as of 18:26, 31 October 2017

spacefill

Our Experimental Results



Below is a diagram of our Sensynova Framework. Clicking on each part of the framework (e.g. detector modules) links to the relevant results.

Alternatively, at the bottom of this page are tabs which will show you results for every part of the project



Framework

Framework Chassis

Biochemical Adaptor

Target

Detector Modules

Multicellular Framework Testing

C12 HSL: Connector 1

Processor Modules

Framework in Cell Free Protein Synthesis Systems

C4 HSL: Connector 2

Reporter Modules



Looking for Interlab Study
related results? Click below!