Difference between revisions of "Team:USMA-West Point/Notebook"

(Begin transcription of notes pertaining to the design of the bioreactor, MEA. MEA: Last Update 1 Jun 2017, Bioreactor: 8 Jun 2017, Fluidics: 9 Jun 2017)
Line 66: Line 66:
 
1 Jun 2017 <br> WO RM AM KP
 
1 Jun 2017 <br> WO RM AM KP
 
<ul>
 
<ul>
<li>Altered the electrode arrangement and size for a single well of a 96 well plate
+
<li>MEA
 +
<ul>
 +
<li>Altered the electrode arrangement and size for a single well of a 96 well plate</li>
 +
<li>Predetermined specifications: Gold or TiN wires, embedded in glass </li>
 
</ul>
 
</ul>
 +
</li>
 +
</ul>
 +
 +
2 Jun 2017<br>
 +
WO RG AM KP MM
 +
<ul>
 +
<li>Determined custom MEA design specs, particularly spacing
 +
</ul>
 +
 +
5 Jun 2017<br>
 +
WO RG AM KP MM
 +
<ul>
 +
<li>Revised MEA spacing
 +
</ul>
 +
 
6 Jun 2017 <br>
 
6 Jun 2017 <br>
WO RG AM KP
+
WO RG AM KP MM
 
<ul>
 
<ul>
 
<li>Discussed the location of holes for media flow and a bubble trap
 
<li>Discussed the location of holes for media flow and a bubble trap
Line 75: Line 93:
  
 
7 Jun 2017 <br>
 
7 Jun 2017 <br>
WO RG AM KP
+
WO RG AM KP MM
 
<ul>
 
<ul>
 
<li>Fleshed out design for bubble trap  
 
<li>Fleshed out design for bubble trap  
Line 81: Line 99:
 
</ul>
 
</ul>
  
8 Jun 2017 <br> WO RG AM KP
+
8 Jun 2017 <br> WO RG AM KP MM
 
<ul>
 
<ul>
<li>Began discussion on removal of olfactant contaminated media while maintaining a perfusion system  
+
<li>Began discussion on removal of olfactant contaminated media while maintaining a perfusion system via syringes
 
<li>Continued clamp design-KP
 
<li>Continued clamp design-KP
 +
<li>Requested a quote for custom MEA
 
</ul>
 
</ul>
  
9 Jun 2017 <br> WO RG AM KP
+
9 Jun 2017 <br> WO RG AM KP MM
<ul>
+
<ul>  
 
<li>Confirmed the use of a peristaltic pump for media flow  
 
<li>Confirmed the use of a peristaltic pump for media flow  
 +
<li>Finalized MEA design
 
</ul>
 
</ul>
 +
 +
12 Jun 2017<br>
 +
WO RG AM KP MM PB
 +
<ul>
 +
<li>Contacted other MEA fabrication companies for quotes
 +
</ul>
 +
 +
13 Jun 2017<br>
 +
WO RG AM KP MM PB
 +
<ul>
 +
<li>Continued search of MEA vendors
 +
<li>Worked on specifics regarding flow into and out of the bioreactor/media reservoirs - decided to use luer locks
 +
</ul>
 +
 +
14 Jun 2017<br>
 +
WO RG AM KP MM PB
 +
<ul>
 +
<li>Continued contacting MEA vendors
 +
</ul>
 +
 +
15 Jun 2017<br>
 +
WO RG AM KP MM PB
 +
<ul>
 +
<li>Determined best luer lock connectors for tubing
 +
<li>Finished printing of clamp design
 +
<li>Explored photomasking vendors
 +
</ul>
 +
 +
16 Jun 2017<br>
 +
WO RG AM KP MM PB
 +
<ul>
 +
<li>Determined design of media reservoirs to be conical flasks 
 +
<li>Explored pre-made MEA vendors
 +
</ul>
 +
 +
 
</html>
 
</html>

Revision as of 16:01, 10 July 2017

USMA-West_Point

Notebook

Document the dates you worked on your project. This should be a detailed account of the work done each day for your project.

What should this page have?
  • Chronological notes of what your team is doing.
  • Brief descriptions of daily important events.
  • Pictures of your progress.
  • Mention who participated in what task.
Inspiration

You can see what others teams have done to organize their notes:

Perfusion System with Bioreactor Design

23 May 2017
WO
  • Began bioreactor design based on former models to be used in a perfusion system
25 May 2017
WO
  • Used AutoDesk Inventor to design a general bioreactor
  • Incorporated shape and general items such as holes for screws and cavity for neuronal culturing
  • Determined location of a multielectrode array (MEA) in bioreactor design, where the neurons would be transfected and tested
30 May 2017
WO
  • Adjusted design of bioreactor design
  • Began a custom design for a MEA
31 May 2017
WO RG AM KP
  • Continued MEA designing: location of electrodes, leads, contact pad spacing, materials
1 Jun 2017
WO RM AM KP
  • MEA
    • Altered the electrode arrangement and size for a single well of a 96 well plate
    • Predetermined specifications: Gold or TiN wires, embedded in glass
2 Jun 2017
WO RG AM KP MM
  • Determined custom MEA design specs, particularly spacing
5 Jun 2017
WO RG AM KP MM
  • Revised MEA spacing
6 Jun 2017
WO RG AM KP MM
  • Discussed the location of holes for media flow and a bubble trap
7 Jun 2017
WO RG AM KP MM
  • Fleshed out design for bubble trap
  • Began design for clamp to keep pins on the multielectrode array (extension of bioreactor) - KP
8 Jun 2017
WO RG AM KP MM
  • Began discussion on removal of olfactant contaminated media while maintaining a perfusion system via syringes
  • Continued clamp design-KP
  • Requested a quote for custom MEA
9 Jun 2017
WO RG AM KP MM
  • Confirmed the use of a peristaltic pump for media flow
  • Finalized MEA design
12 Jun 2017
WO RG AM KP MM PB
  • Contacted other MEA fabrication companies for quotes
13 Jun 2017
WO RG AM KP MM PB
  • Continued search of MEA vendors
  • Worked on specifics regarding flow into and out of the bioreactor/media reservoirs - decided to use luer locks
14 Jun 2017
WO RG AM KP MM PB
  • Continued contacting MEA vendors
15 Jun 2017
WO RG AM KP MM PB
  • Determined best luer lock connectors for tubing
  • Finished printing of clamp design
  • Explored photomasking vendors
16 Jun 2017
WO RG AM KP MM PB
  • Determined design of media reservoirs to be conical flasks
  • Explored pre-made MEA vendors