+ | <h3>Perfusion System with Bioreactor Design</h3> | ||
+ | |||
+ | 23 May 2017 | ||
+ | <br> WO | ||
+ | <ul> | ||
+ | <li>Began bioreactor design based on former models to be used in a perfusion system | ||
+ | </ul> | ||
+ | |||
+ | 25 May 2017 | ||
+ | <br>WO | ||
+ | <ul> | ||
+ | <li>Used AutoDesk Inventor to design a general bioreactor | ||
+ | <li>Incorporated shape and general items such as holes for screws and cavity for neuronal culturing | ||
+ | <li>Determined location of a multielectrode array (MEA) in bioreactor design, where the neurons would be transfected and tested | ||
+ | </ul> | ||
+ | |||
+ | |||
+ | 30 May 2017 <br> WO | ||
+ | <ul> | ||
+ | <li>Adjusted design of bioreactor design | ||
+ | <li>Began a custom design for a MEA | ||
+ | </ul> | ||
+ | |||
+ | 31 May 2017 <br> WO RG AM KP | ||
+ | <ul> | ||
+ | <li>Continued MEA designing: location of electrodes, leads, contact pad spacing, materials | ||
+ | </ul> | ||
+ | |||
+ | 1 Jun 2017 <br> WO RM AM KP | ||
+ | <ul> | ||
+ | <li>Altered the electrode arrangement and size for a single well of a 96 well plate | ||
+ | </ul> | ||
+ | 6 Jun 2017 <br> | ||
+ | WO RG AM KP | ||
+ | <ul> | ||
+ | <li>Discussed the location of holes for media flow and a bubble trap | ||
+ | </ul> | ||
+ | |||
+ | 7 Jun 2017 <br> | ||
+ | WO RG AM KP | ||
+ | <ul> | ||
+ | <li>Fleshed out design for bubble trap | ||
+ | <li>Began design for clamp to keep pins on the multielectrode array (extension of bioreactor) - KP | ||
+ | </ul> | ||
+ | |||
+ | 8 Jun 2017 <br> WO RG AM KP | ||
+ | <ul> | ||
+ | <li>Began discussion on removal of olfactant contaminated media while maintaining a perfusion system | ||
+ | <li>Continued clamp design-KP | ||
+ | </ul> | ||
+ | |||
+ | 9 Jun 2017 <br> WO RG AM KP | ||
+ | <ul> | ||
+ | <li>Confirmed the use of a peristaltic pump for media flow | ||
+ | </ul> | ||
</html> | </html> |
Revision as of 18:30, 7 July 2017
USMA-West_Point
Notebook
Document the dates you worked on your project. This should be a detailed account of the work done each day for your project.
What should this page have?
- Chronological notes of what your team is doing.
- Brief descriptions of daily important events.
- Pictures of your progress.
- Mention who participated in what task.
Inspiration
You can see what others teams have done to organize their notes:
Perfusion System with Bioreactor Design
23 May 2017WO
- Began bioreactor design based on former models to be used in a perfusion system
WO
- Used AutoDesk Inventor to design a general bioreactor
- Incorporated shape and general items such as holes for screws and cavity for neuronal culturing
- Determined location of a multielectrode array (MEA) in bioreactor design, where the neurons would be transfected and tested
WO
- Adjusted design of bioreactor design
- Began a custom design for a MEA
WO RG AM KP
- Continued MEA designing: location of electrodes, leads, contact pad spacing, materials
WO RM AM KP
- Altered the electrode arrangement and size for a single well of a 96 well plate
WO RG AM KP
- Discussed the location of holes for media flow and a bubble trap
WO RG AM KP
- Fleshed out design for bubble trap
- Began design for clamp to keep pins on the multielectrode array (extension of bioreactor) - KP
WO RG AM KP
- Began discussion on removal of olfactant contaminated media while maintaining a perfusion system
- Continued clamp design-KP
WO RG AM KP
- Confirmed the use of a peristaltic pump for media flow