Difference between revisions of "Team:UrbanTundra Edmonton/InterLab"

 
(16 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{UrbanTundra_Edmonton/Header}}
 +
{{Team:UrbanTundra Edmonton/nav bar}}
 +
 
<html>
 
<html>
  
<head>
+
          <div class="col-md-9 animate-box ute-heading main-content">
    <title>Our Story</title>
+
            <h1>InterLab</h1>
    <link rel="stylesheet" href="https://cdnjs.cloudflare.com/ajax/libs/normalize/5.0.0/normalize.min.css">
+
            <div class="breadcrumb" style="width: 100%">
    <link rel="stylesheet" href="https://2017.igem.org/Template:UrbanTundra_Edmonton/TimelineStyle?action=raw&ctype=text/css">
+
            </div>
</head>
+
            <h3>Background</h3>
</html>
+
            <p>This year, our team participated in the fourth InterLab Measurement Study which aimed to establish and test a standardized protocol to measure GFP that can produce common and consistent numbers from all across the world. Doing our part, we used a plate reader, which we were given access to from the UAlberta iGEM team along with support from members of the UAlberta iGEM team to measure GFP fluorescence. Our team followed the protocols outlined in the <a href="https://2017.igem.org/Competition/InterLab_Study">iGEM InterLab page</a>.</p>
 +
           
 +
            <h3>Materials</h3>
 +
            <p><b>Plasmids used:</b><br>Devices (from InterLab Measurement Kit):<br>Positive control<br>Negative control<br>Test Device 1: J23101+I13504<br>Test Device 2: J23106+I13504<br>Test Device 3: J23117+I13504<br>Test Device 4: J23101.BCD2.E0040.B0015<br>Test Device 5: J23106.BCD2.E0040.B0015<br>Test Device 6: J23117.BCD2.E0040.B0015</p>  
 +
            <p><b>Strain used:</b><br>Competent cells (Escherichia coli strain DH5α)</p>
 +
            <p><b>Materials used:</b><br>LB (Luria Bertani) media<br>  
 +
Chloramphenicol (stock concentration 25 mg/mL dissolved in EtOH - working stock 25 ug/mL)<br>50 ml Falcon tube (covered in foil to block light)<br>Incubator at 37°C<br>1.5 ml eppendorf tubes for sample storage<br>Ice bucket with ice<br>Pipettes<br>96 well plate, black with flat, transparent/clear bottom preferred (provided by UAlberta team)</p>
 +
<p><b>Plate reader used:</b><br>Tecan SAFIRE II Multi-mode Plate Reader</p>
  
{{UrbanTundra_Edmonton/Header}}
+
            <h3>Protocol</h3>
 +
<img class="sponsors" src="https://static.igem.org/mediawiki/2017/5/5f/ABS600_VS._Time.png" class="img-responsive" height="400px">
  
<html>
+
<img class="sponsors" src="https://static.igem.org/mediawiki/2017/7/70/Fluorescence_VS._Time.png" class="img-responsive" height="400px">
<body translate="no">
+
  
<div class="container" style="margin-top: 100px">
+
<img class="sponsors" src="https://static.igem.org/mediawiki/2017/e/e9/OD600_Reference_Point.png" class="img-responsive" height="400px">
<div class="row">
+
 
<div class="col-lg-12 ute-heading animate-box fadeInUp animated">
+
<img class="sponsors" src="https://static.igem.org/mediawiki/2017/c/c9/UM_Fluorescein_OD600.png" class="img-responsive" height="400px">
<h1 style="font-weight: 700">InterLab</h1>
+
 
<p>Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat. Ut wisi enim ad minim veniam, quis nostrud exerci tation ullamcorper suscipit lobortis nisl ut aliquip ex ea commodo consequat. Duis autem vel eum iriure dolor in hendrerit in vulputate velit esse molestie consequat, vel illum dolore eu feugiat nulla facilisis at vero eros et accumsan et iusto odio dignissim qui blandit praesent luptatum zzril delenit augue duis dolore te feugait nulla facilisi.
+
            <h3>Discussion</h3>
.</p>
+
            <p>Looking at the data curves of our graphs, there is a linear relation at low concentrations of fluorescein but as the concentration increases, the curve plateaus. This suggests that our detector may have been oversaturated.</p>
</div>
+
 
 +
          </div>
 
</div>
 
</div>
</div>
+
</div>
 +
</div>
 +
  <script src="http://ajax.googleapis.com/ajax/libs/jquery/2.1.1/jquery.min.js"></script>
 +
<script>
  
</html>
+
$(function () {
  
 +
      var links = $('.sidebar-links > div');
 +
 +
      links.on('click', function () {
 +
        if ($(this).hasClass('selected')){
 +
          links.removeClass('selected');
 +
        } else {
 +
          links.removeClass('selected');
 +
          $(this).addClass('selected');
 +
        }
 +
      });
 +
    });
 +
 +
</script>
 +
</html>
  
 
{{UrbanTundra_Edmonton/Footer}}
 
{{UrbanTundra_Edmonton/Footer}}

Latest revision as of 03:55, 2 November 2017

Urban Tundra | Intelligent Innovation

InterLab

Background

This year, our team participated in the fourth InterLab Measurement Study which aimed to establish and test a standardized protocol to measure GFP that can produce common and consistent numbers from all across the world. Doing our part, we used a plate reader, which we were given access to from the UAlberta iGEM team along with support from members of the UAlberta iGEM team to measure GFP fluorescence. Our team followed the protocols outlined in the iGEM InterLab page.

Materials

Plasmids used:
Devices (from InterLab Measurement Kit):
Positive control
Negative control
Test Device 1: J23101+I13504
Test Device 2: J23106+I13504
Test Device 3: J23117+I13504
Test Device 4: J23101.BCD2.E0040.B0015
Test Device 5: J23106.BCD2.E0040.B0015
Test Device 6: J23117.BCD2.E0040.B0015

Strain used:
Competent cells (Escherichia coli strain DH5α)

Materials used:
LB (Luria Bertani) media
Chloramphenicol (stock concentration 25 mg/mL dissolved in EtOH - working stock 25 ug/mL)
50 ml Falcon tube (covered in foil to block light)
Incubator at 37°C
1.5 ml eppendorf tubes for sample storage
Ice bucket with ice
Pipettes
96 well plate, black with flat, transparent/clear bottom preferred (provided by UAlberta team)

Plate reader used:
Tecan SAFIRE II Multi-mode Plate Reader

Protocol

Discussion

Looking at the data curves of our graphs, there is a linear relation at low concentrations of fluorescein but as the concentration increases, the curve plateaus. This suggests that our detector may have been oversaturated.