Line 6: | Line 6: | ||
</p> | </p> | ||
<p style="font-size:70%"> | <p style="font-size:70%"> | ||
− | <img src="https://static.igem.org/mediawiki/2017/thumb/6/6e/T--Munich--pic--lysis_pcr_deltatemp.png/ | + | <img src="https://static.igem.org/mediawiki/2017/thumb/6/6e/T--Munich--pic--lysis_pcr_deltatemp.png/765px-T--Munich--pic--lysis_pcr_deltatemp.png"> </br> |
[1] 65 °C, [2] log2 DNA ladder, [3] 70 °C, [4] 75 °C, [5] 80 °C, [6] 85 °C, [7] 90 °C, [8] empty °C, [9] positive control (DNA sequence diluted), [10] log2 DNA ladder </br> | [1] 65 °C, [2] log2 DNA ladder, [3] 70 °C, [4] 75 °C, [5] 80 °C, [6] 85 °C, [7] 90 °C, [8] empty °C, [9] positive control (DNA sequence diluted), [10] log2 DNA ladder </br> | ||
2 uL of lysed E. Coli suspension with density of 10^6 cells/ml used for PCR-Mix. | 2 uL of lysed E. Coli suspension with density of 10^6 cells/ml used for PCR-Mix. | ||
Line 15: | Line 15: | ||
</p> | </p> | ||
<p style="font-size:70%"> | <p style="font-size:70%"> | ||
− | <img src="https://static.igem.org/mediawiki/2017 | + | <img src="https://static.igem.org/mediawiki/2017/e/e0/T--Munich--pic--lysis_pcr_deltacells.png"> </br> |
[1] log2 DNA ladder, [2] 10^6 cells/ml, [3] 10^5 cells/ml, [4] 5*10^4 cells/ml, [5] 10^4 cells/ml,[6] 5*10^3 cells/ml, [7] 10^3 cells/ml, [8] 10^2 cells/ml,[9] 10^6 cells/ml (no heat-step. only PCR at 37 °C) | [1] log2 DNA ladder, [2] 10^6 cells/ml, [3] 10^5 cells/ml, [4] 5*10^4 cells/ml, [5] 10^4 cells/ml,[6] 5*10^3 cells/ml, [7] 10^3 cells/ml, [8] 10^2 cells/ml,[9] 10^6 cells/ml (no heat-step. only PCR at 37 °C) | ||
</p> | </p> |
Revision as of 12:18, 28 October 2017
Cell Lysis
From our Urea page gel, we conclude that alkaline lysis, as frequently used for plasmid extraction, is a very fast way of extracting RNA. It is commonly known that RNA (unlike DNA) swiftly self-degredates at high pH, and this also showed in our experiments. Comparison between different incubation times shows clearly the continuing degredation over time. Within only a few seconds of inverting tubes, RNA is already cut and thus shortened, as the two "NaOH, 0 min" bars show. However, the target sequence of Cas13a is very short (~ 20 base pairs) and we deem it unlikely that a significant percentage of target-sequences is destroyed by a very fast lysis. Most of the cut strands are still well above 200 bp for a "seconds-long" lysis, with the peak of brightness between the 500 bp and 1000 bp mark, as the gradient of band intensity shows. With higher incubation times, the peak of brightness goes steadily lower, and even under 200 bp for a incubation time of 10 minutes. It is thus of utmost importance to keep the lysis time to a few seconds, which makes a proper and fast mixing of the sample with alkalic lysis buffer and seconds later with acidic equilibration buffer necessary. Since microfluidic mixing of liquids is a rather complex process, we chose a tecnically simpler approach to extract pathogen RNA in our first prototype: Isothermal PCR.
[1] 65 °C, [2] log2 DNA ladder, [3] 70 °C, [4] 75 °C, [5] 80 °C, [6] 85 °C, [7] 90 °C, [8] empty °C, [9] positive control (DNA sequence diluted), [10] log2 DNA ladder 2 uL of lysed E. Coli suspension with density of 10^6 cells/ml used for PCR-Mix.
PCR is a common method in analytics to achieve huge amplification of genetic material. It allows us to use a relatively inefficient lysis method, lysis by heat only, and increases the resulting low concentration of target sequence to above a detectable threshold. With Reverse Transcription before, it is also possible to amplify an RNA sequence as DNA.
To increase the detection threshold of our system with PCR, it is however still important to optimize the heat lysis parameters, most prominently the temperature at which to incubate. It has been shown, at least for protein extraction
[1] log2 DNA ladder, [2] 10^6 cells/ml, [3] 10^5 cells/ml, [4] 5*10^4 cells/ml, [5] 10^4 cells/ml,[6] 5*10^3 cells/ml, [7] 10^3 cells/ml, [8] 10^2 cells/ml,[9] 10^6 cells/ml (no heat-step. only PCR at 37 °C)
To assess the theoretical sensibility of our PCR-enhanced lysis, we did tests on a dilution series of a E. coli with TEV-plasmid (psB1C3-His-008-TEV) culture with a cell density range from 10^6 to 10^2 cells/ml. After lysis at 80 °C, the isothermal PCR was performed on 2 uL of lysed sample. The gel shows a clearly visible band of PCR product down to a cell density of 5*10^4 cells/ml. Image processing even reveals low PCR-product concentration at 10^4 cell/ml, which corresponds to on average 20 cells in the PCR reaction volume. This fits nicely with our findings that heat-only lysis is less efficient by a factor of 5 to 10 when compared to lysis with detergents and heat (see labbook).