(15 intermediate revisions by 5 users not shown) | |||
Line 74: | Line 74: | ||
<td id="myContent" width="20%" valign=top align=center> | <td id="myContent" width="20%" valign=top align=center> | ||
<br> | <br> | ||
− | |||
<!-- Content Begin --> | <!-- Content Begin --> | ||
− | <img id="TopPicture" width="960" src="https://static.igem.org/mediawiki/2017/ | + | <img id="TopPicture" width="960" src="https://static.igem.org/mediawiki/2017/1/1c/T--Munich--FrontPagePictures_SampleProcessing.jpg"> |
<table width="960" border=0 cellspacing=0 cellpadding=10> | <table width="960" border=0 cellspacing=0 cellpadding=10> | ||
<tr> | <tr> | ||
Line 90: | Line 89: | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | |||
Line 100: | Line 100: | ||
</p> | </p> | ||
<p> | <p> | ||
− | Here, we present an early prototype that addresses these criteria. We created the chip from PDMS via <a class="myLink" | + | Here, we present an early prototype that addresses these criteria. We created the chip from PDMS via <a class="myLink" href="https://2017.igem.org/Team:Munich/Protocols">soft lithography</a>, using 3D-printed molds to speed up prototyping cycles compared to photolithography-based methods. |
</p> | </p> | ||
<p> | <p> | ||
Line 121: | Line 121: | ||
</p> | </p> | ||
<div class="captionPicture"> | <div class="captionPicture"> | ||
− | <img src="https://static.igem.org/mediawiki/2017/ | + | <img src="https://static.igem.org/mediawiki/2017/b/bb/Pdms_open_labeled.svg"> |
<p> | <p> | ||
Labelled PDMS chip. | Labelled PDMS chip. | ||
Line 129: | Line 129: | ||
<h3>Thermolysis and Isothermal PCR </h3> | <h3>Thermolysis and Isothermal PCR </h3> | ||
<p> | <p> | ||
− | Our wetlab experiments showed that thermolysis at 80°C followed by isothermal amplification of the pathogen RNA via Recombinase Polymerase Amplification (RPA) combined with | + | Our wetlab experiments showed that thermolysis at 80°C followed by isothermal amplification of the pathogen RNA via Recombinase Polymerase Amplification (RPA) combined with transcription at 37°C provides a reliable and non-hazardous procedure that yields concentrations of target RNA that are detectable by Cas13a. The sample stays in the lysis chamber for 2 minutes and then passes through cooling loops to prevent heat denaturation of the lyophilized protein, which is stored in the RPA chamber. The amplification is conducted for 1.5 hours and finally the processed sample is released onto the paper strip for the readout reaction. |
</p> | </p> | ||
<h3>Temperature control unit</h3> | <h3>Temperature control unit</h3> | ||
Line 138: | Line 138: | ||
<img src="https://static.igem.org/mediawiki/2017/7/78/T--Munich--Hardware_explodeheater.svg"> | <img src="https://static.igem.org/mediawiki/2017/7/78/T--Munich--Hardware_explodeheater.svg"> | ||
<p> | <p> | ||
− | + | Exploded heater. | |
</p> | </p> | ||
− | |||
</div> | </div> | ||
+ | <p> | ||
+ | We connected the Peltier elements to relays and wrote a temperature control program that we ran on a Raspberry Pie 3, which would turn on the elements until the sensor has measured a certain temperature and turn it off until the temperature drops back to a given value. As a power source, we used a common power bank, making the device portable. This way we were able to create simple, fast heating and low-cost constant temperature chambers for the lysis and isothermal PCR. | ||
+ | </p> | ||
+ | <div class="captionPicture"> | ||
+ | <img width= 800 src="https://static.igem.org/mediawiki/2017/8/85/T--Munich--HardwarePagePictures-Heatbringer.png"> | ||
+ | <p> | ||
+ | Plug plan for our temperature control system. | ||
+ | </p> | ||
+ | </div> | ||
+ | |||
+ | <h3>Outlook</h3> | ||
+ | <p> | ||
+ | For the final product we plan to strongly scale down our current chip design to reduce reaction volumes, material consumption and increase portability. This requires to adapt techniques for mold production with a better resolution like photolithography and proper choice of a chip material suitable for mass production. | ||
+ | </p> | ||
+ | <p> | ||
+ | This disposable microfluidic chip would then be loaded with the sample and inserted into a reusable device that integrates fluid control, thermolysis and amplification with the detection unit and conducts all the steps automatically. | ||
+ | </p> | ||
</td> | </td> |
Latest revision as of 00:24, 2 November 2017
| |||||||||||||||||||||||||||||||||||||||||||||
|