Difference between revisions of "Team:XMU-China/Description"

 
(20 intermediate revisions by 3 users not shown)
Line 12: Line 12:
 
<link href="https://2017.igem.org/Team:XMU-China/css/unitcommomCss?action=raw&ctype=text/css" rel="stylesheet" type="text/css">
 
<link href="https://2017.igem.org/Team:XMU-China/css/unitcommomCss?action=raw&ctype=text/css" rel="stylesheet" type="text/css">
 
<link href="https://2017.igem.org/Team:XMU-China/css/leftguideCss?action=raw&ctype=text/css" rel="stylesheet" type="text/css">
 
<link href="https://2017.igem.org/Team:XMU-China/css/leftguideCss?action=raw&ctype=text/css" rel="stylesheet" type="text/css">
 +
<link href="https://2017.igem.org/Team:XMU-China/css/cebianlanCss?action=raw&ctype=text/css" rel="stylesheet" type="text/css">
 
</head>
 
</head>
  
Line 31: Line 32:
 
<li><a href="https://2017.igem.org/Team:XMU-China/Demonstrate">Demonstrate</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Demonstrate">Demonstrate</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Results">Results</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Results">Results</a></li>
<li><a href="https://2017.igem.org/Team:XMU-China/Measurement">Measurement</a></li>
+
<li><a href="https://2017.igem.org/Team:XMU-China/Applied_Design">Applied&nbsp;Design</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Parts">Parts</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Parts">Parts</a></li>
 
</ul>
 
</ul>
Line 49: Line 50:
 
<ul style="dropdown-menu">
 
<ul style="dropdown-menu">
 
<li><a href="https://2017.igem.org/Team:XMU-China/Hardware">Overview</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Hardware">Overview</a></li>
 +
<li><a href="https://2017.igem.org/Team:XMU-China/Freeze-Dry">Freeze-Dry</a></li>
 +
<li><a href="https://2017.igem.org/Team:XMU-China/East-Wind">East-Wind</a></li>
 +
<li><a href="https://2017.igem.org/Team:XMU-China/Accessories">Accessories</a></li>
 +
<li><a href="https://2017.igem.org/Team:XMU-China/More_Chips">More&nbsp;Chips</a></li>
 
</ul>
 
</ul>
 
</li>
 
</li>
Line 56: Line 61:
 
<ul style="dropdown-menu">
 
<ul style="dropdown-menu">
 
<li><a href="https://2017.igem.org/Team:XMU-China/Model">Overview</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Model">Overview</a></li>
<li><a href="https://2017.igem.org/Team:XMU-China/Model_Method">Method</a></li>
+
<li><a href="https://2017.igem.org/Team:XMU-China/Modeling">Modeling</a></li>
 
</ul>
 
</ul>
 
</li>
 
</li>
Line 78: Line 83:
 
<li><a href="https://2017.igem.org/Team:XMU-China/Contribution">Contribution</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Contribution">Contribution</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Improve">Improve</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Improve">Improve</a></li>
 +
<li><a href="https://2017.igem.org/Team:XMU-China/Measurement">Measurement</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Safety">Safety</a></li>
 
<li><a href="https://2017.igem.org/Team:XMU-China/Safety">Safety</a></li>
 
</ul>
 
</ul>
Line 92: Line 98:
  
 
</ul>
 
</ul>
 
 
</div>
 
</div>
 
<!--end guide-->
 
<!--end guide-->
Line 101: Line 106:
 
</div>
 
</div>
 
<!--end title-->
 
<!--end title-->
 +
<!--cebian guide-->
 +
<div id="float">
 +
<div id="cebianlan">
 +
<div class="menu-list"><a href="#subtitle1">Background</a></div>
 +
<div class="menu-list"><a href="#subtitle2">Abstract</a></div>
 +
</div></div>
 +
 +
<script type="text/javascript">
 +
window.onload=
 +
function(){
 +
    var oDiv = document.getElementById("float"),
 +
    H = 60,
 +
    Y = oDiv
 +
    while (Y) {H += Y.offsetTop; Y = Y.offsetParent}
 +
    window.onscroll = function()
 +
    {
 +
        var s = document.body.scrollTop || document.documentElement.scrollTop
 +
        if(s>H) {
 +
            oDiv.style = "position:fixed;top:20px;"
 +
        } else {
 +
            oDiv.style = ""
 +
        }
 +
    }
 +
}
 +
</script>
 +
<!--end cebian guide-->
 +
  
<!--left guide-->
 
<ul class="pageScroll left">
 
<li class="scrollNav scrollNav_2"><a href="#subtitle1"></a></li>
 
<li class="scrollNav scrollNav_2"><a href="#subtitle2"></a></li>
 
<li class="scrollNav scrollNav_3"><a href="#subtitle3"></a></li>
 
</ul>
 
<!--end left guide-->
 
  
  
 
<!--column-->
 
<!--column-->
 
<div class="column" id="column">
 
<div class="column" id="column">
<span class="subtitle" id="subtitle1">--------* Background *--------</span>
+
 
<p>Heavy pollution has long plagued the people. How to detect the concentration of heavy metal ions and how to decrease the detection limit as much as possible have become a challenging task.<br /><br />
+
<span class="blank" id="subtitle1"></span><span class="subtitle" >--------* Background *--------</span>
Now the most common and sensitive method of detecting trace heavy metals is atomic absorption spectrometry(AAS). But this method requires expensive instruments, and the operation is also cumbersome. So the AAS is limited to professional testing organizations and scientific research institutions to use. In addition, although there have been test paper, detection kits and other low-cost products which can be used to detect heavy metals, they also face the problem of  low efficiency, poor sensitivity, tedious work and so on. So the existing detection technology is not suitable for the general population to use.<br /><br />
+
<p>Toxic ions pollution in water has long plagued people. How to detect the concentration of toxic ions and how to decrease the detection limit as much as possible have become a challenging task.<br /><br />
Although there were many iGEM teams also trying to design a variety of detecting systems to detect pollutants, they have many defections that the detection limit is high and that the detection time is long. So to find a better way of detecting very small quantities of heavy metals, something like the biological signal-amplifiers, the microfluidic chips and the portable hardwares is are necessary.<br /><br />
+
The most common and sensitive methods of detecting trace toxic ions today are based on instrumental analysis, such as Atomic Absorption Spectrometry(AAS) and Inductive Coupled Plasma Emission Spectrometer(ICP), however, these methods require expensive instruments, and the operation is cumbersome as well. Hence the applications of these methods are limited to professional testing organizations and scientific research institutions. In addition, although there have been test paper, detection kits and other low-cost products which can be used to detect toxic ions, they also face the problems such as low efficiency, poor sensitivity, and tedious process. Thus the existing detection technology is not suitable for the general population to use.<br /><br />
An interesting method to detect the concentration of ions using Escherichia coli is to select the corresponding metal-sensitive promoters binding with the reporter genes like the fluorescent protein genes. By constructing this kind of recombinant plasmids, the concentration signal can be transferred into the semi-quantitatively detectable signal like electric current and so on. But the detection limit is so low that only high level accumulation of heavy metals in the environment can be detected. To solve this problem, we aim to develop an amplifier to detect <strong>semi-quantitativly</strong> the concentration of the heavy metal ions including the metals with small volume.<br /><br />
+
Although there were many iGEM teams trying to design a variety of detecting systems to detect pollutants as the same as us, they might have many defections such as the detection limit is high and that the detection time is long. In order to find a better way of detecting comparably small quantities of toxic ions, methods such as the biological signal-amplifiers, the microfluidic chips and the portable hardware are of great importance and practical significance. .<br /><br />
<span class="descriptionimg" style="display:inline-block;width:100%;text-align:center;"><img class="descriptionimg1" style="width:60%;" src="#"></span></p>
+
An interesting method to detect the concentration of ions using <em>Escherichia coli</em> is to select the corresponding ion-sensitive promoters binding with the reporter genes like the fluorescent protein genes. By constructing this kind of recombinant plasmids, the concentration signal can be transferred into a semi-quantitatively detectable signal like electric current and so on. However, the detection limit is extremely low that only high level accumulation of toxic ions in the environment can be detected. To solve this problem, we aimed to construct an amplifier to detect the concentration of the toxic ions including the ions <strong>semi-quantitativly</strong> with small volume.<br /><br />
<span class="blank"></span>
+
<span class="descriptionimg" style="display:inline-block;width:100%;text-align:center;"><img class="descriptionimg1" style="width:60%;" src="https://static.igem.org/mediawiki/2017/d/db/T--XMU-China--descriptionimg1.png"></span></p>
<span class="subtitle"id="subtitle2">--------* Abstract *--------</span>
+
<span class="blank"  id="subtitle2"></span>
 +
<span class="subtitle">--------* Abstract *--------</span>
 
<p>A sensitive detector for harmful ions in water based on a chip<br /><br />
 
<p>A sensitive detector for harmful ions in water based on a chip<br /><br />
 
<span class="descriptionimg" style="display:inline-block;width:100%;text-align:center;"><img class="descriptionimg2" style="width:60%;" src="https://static.igem.org/mediawiki/2017/d/d0/T--XMU-China--hpoverviewimg2.jpeg"></span><br /><br />
 
<span class="descriptionimg" style="display:inline-block;width:100%;text-align:center;"><img class="descriptionimg2" style="width:60%;" src="https://static.igem.org/mediawiki/2017/d/d0/T--XMU-China--hpoverviewimg2.jpeg"></span><br /><br />
Arsenic contamination in drinking water has long been a serious problem in many countries throughout the world, including China and the US. So XMU_China hopes to provide a sensitive and user-friendly device to detect arsenic in water. A microfluid chip is designed and produced to achieve our goal. The chip is a arsenic detector containing genetically modified E.coli that is able to express green fluorescent protein or lacZ in response to the concentration of arsenic. By calibrating the fluorescence intensity or current strength caused by luciferase or lacZ respectively, a whole range of arsenic levels in water can be detected.<br /><br />
+
Arsenic contamination in drinking water has long been a serious problem in many countries throughout the world, including China and the US. In this circumstance, XMU-China hopes to provide a sensitive and user-friendly device to detect arsenic in water and a microfluid chip is designed and produced to achieve our goal. The chip is an arsenic detector containing genetically modified E.coli that is able to express green fluorescent protein or lacZ in response to a certain range of arsenic concentration of arsenic. By calibrating the fluorescence intensity or current strength caused by luciferase or lacZ respectively, a whole range of arsenic levels in water can be detected.<br /><br />
We also plan to use this chip model to detect other metal ions such as iron and mercury. To simplify the process, we will adopt a certain universal approach by constructing a common intermediate which can eliminate the differences among detection of different metal ions. And T7 induced expression system is used to realize the effect of amplifying the signal in response to these ions. What’s more, we try to explore potential application of iLOV, a kind of small FMN-based fluorescent protein, to detect and recycle these harmful ions because of its inherent, binding properties towards them with high affinity.</p>
+
We also plan to use this chip model to detect other harmful ions such as iron and mercury. To simplify the process, we will adopt a certain universal approach by constructing a common intermediate which can eliminate the differences among detection of different harmful ions. And T7 induced expression system is used to realize the effect of amplifying the signal in response to these ions. What’s more, we try to explore potential application of iLOV, a kind of small FMN-based fluorescent protein, to detect and recycle these harmful ions because of its inherent, binding properties towards them with high affinity.</p>
 
<span class="blank"></span>
 
<span class="blank"></span>
 
</div>
 
</div>

Latest revision as of 03:37, 2 November 2017

2017.igem.org/Team:XMU-China/Description

--------* Background *--------

Toxic ions pollution in water has long plagued people. How to detect the concentration of toxic ions and how to decrease the detection limit as much as possible have become a challenging task.

The most common and sensitive methods of detecting trace toxic ions today are based on instrumental analysis, such as Atomic Absorption Spectrometry(AAS) and Inductive Coupled Plasma Emission Spectrometer(ICP), however, these methods require expensive instruments, and the operation is cumbersome as well. Hence the applications of these methods are limited to professional testing organizations and scientific research institutions. In addition, although there have been test paper, detection kits and other low-cost products which can be used to detect toxic ions, they also face the problems such as low efficiency, poor sensitivity, and tedious process. Thus the existing detection technology is not suitable for the general population to use.

Although there were many iGEM teams trying to design a variety of detecting systems to detect pollutants as the same as us, they might have many defections such as the detection limit is high and that the detection time is long. In order to find a better way of detecting comparably small quantities of toxic ions, methods such as the biological signal-amplifiers, the microfluidic chips and the portable hardware are of great importance and practical significance. .

An interesting method to detect the concentration of ions using Escherichia coli is to select the corresponding ion-sensitive promoters binding with the reporter genes like the fluorescent protein genes. By constructing this kind of recombinant plasmids, the concentration signal can be transferred into a semi-quantitatively detectable signal like electric current and so on. However, the detection limit is extremely low that only high level accumulation of toxic ions in the environment can be detected. To solve this problem, we aimed to construct an amplifier to detect the concentration of the toxic ions including the ions semi-quantitativly with small volume.

--------* Abstract *--------

A sensitive detector for harmful ions in water based on a chip



Arsenic contamination in drinking water has long been a serious problem in many countries throughout the world, including China and the US. In this circumstance, XMU-China hopes to provide a sensitive and user-friendly device to detect arsenic in water and a microfluid chip is designed and produced to achieve our goal. The chip is an arsenic detector containing genetically modified E.coli that is able to express green fluorescent protein or lacZ in response to a certain range of arsenic concentration of arsenic. By calibrating the fluorescence intensity or current strength caused by luciferase or lacZ respectively, a whole range of arsenic levels in water can be detected.

We also plan to use this chip model to detect other harmful ions such as iron and mercury. To simplify the process, we will adopt a certain universal approach by constructing a common intermediate which can eliminate the differences among detection of different harmful ions. And T7 induced expression system is used to realize the effect of amplifying the signal in response to these ions. What’s more, we try to explore potential application of iLOV, a kind of small FMN-based fluorescent protein, to detect and recycle these harmful ions because of its inherent, binding properties towards them with high affinity.