(7 intermediate revisions by 3 users not shown) | |||
Line 110: | Line 110: | ||
<tr><td colspan=6 align=left valign=center> | <tr><td colspan=6 align=left valign=center> | ||
<div style="margin-top: 40px"><font size=7 color=#51a7f9><b style="color: #51a7f9">Results: Detection on Chip</b></font></div> | <div style="margin-top: 40px"><font size=7 color=#51a7f9><b style="color: #51a7f9">Results: Detection on Chip</b></font></div> | ||
+ | </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="6"> | ||
+ | <h3>What worked:</h3> | ||
+ | <ul class="listResults"> | ||
+ | <li>We characterized Cas13a and its detection limit with native and <a class="myLink" href="https://2017.igem.org/Team:Munich/DetectionOnChip#lyophi">lyophilized</a> protein, with | ||
+ | <a class="myLink" href="https://2017.igem.org/Team:Munich/Cas13a#Figure_1">in vitro</a> and <a class="myLink" href="https://2017.igem.org/Team:Munich/Cas13a#vivo">in vivo</a> sources of RNA, in bulk and <a class="myLink" href="https://2017.igem.org/Team:Munich/DetectionOnChip#onpaper2">on paper</a>. </li> | ||
+ | <li>We optimized the <a class="myLink" href="https://2017.igem.org/Team:Munich/DetectionOnChip#onpaper2"> paper support</a> for Cas13a functionality.</li> | ||
+ | <li>We built the <a class="myLink" href="https://2017.igem.org/Team:Munich/Hardware/Detector#sensitivity"> most sensitive</a> and <a class="myLink" href="https://2017.igem.org/Team:Munich/Hardware/Detector#cost">cheapest</a> fluorescence detector <a class="myLink" href="https://2017.igem.org/Team:Munich/DetectionOnChip#detectorB">ever created by an iGEM team</a> to our knowledge. | ||
+ | </li> | ||
+ | <li>We successfully used our fluorescence detector to <a class="myLink" href="https://2017.igem.org/Team:Munich/DetectionOnChip#detectorA"> detect Cas13a activity</a> on paper.</li> | ||
+ | </ul> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td colspan="6"> | ||
+ | <h3>What presented issues:</h3> | ||
+ | <ul class="listResults"> | ||
+ | <li>Optimizing the lyophilization and stability of Cas13a.</li> | ||
+ | </ul> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 126: | Line 148: | ||
<p> | <p> | ||
First, we needed to optimize the paper on which the detection was done. We found that our detection circuit was hindered on nitrocellulose paper, and that the best support was glass fiber filter paper blocked with 5% BSA overnight, rinsed with RNase-free water and dried in the oven (70°C, 20 minutes). </p><p> | First, we needed to optimize the paper on which the detection was done. We found that our detection circuit was hindered on nitrocellulose paper, and that the best support was glass fiber filter paper blocked with 5% BSA overnight, rinsed with RNase-free water and dried in the oven (70°C, 20 minutes). </p><p> | ||
− | As a first simple test, we pipetted our reaction mixture on the paper, sandwiched the strip in coverslips and pinched the paper in a <a class="myLink" href="https://github.com/igemsoftware2017/igem_munich_2017/tree/master/3D_Prints | + | As a first simple test, we pipetted our reaction mixture on the paper, sandwiched the strip in coverslips and pinched the paper in a <a class="myLink" href="https://github.com/igemsoftware2017/igem_munich_2017/tree/master/3D_Prints">3D-printed 96-well plate</a>, to avoid any artefacts caused by evaporation, curling of the paper or similar effects. We could then measure the fluorescence in a plate reader. We found the kinetics to be similar to bulk, and the detection limit to be between 10 nM and 50 nM <b>(Figure 1)</b>. This is similar to the detection limit in bulk experiments, but as in this particular set of experiment, we did not have a positive control, we cannot normalise the amount of cleaved RNaseAlert and directly compare the titration curves. </p> |
<div class="captionPicture"> | <div class="captionPicture"> | ||
<img width=740 src="https://static.igem.org/mediawiki/2017/a/a9/T--Munich--DetectionChip_Detection_Circuit.png"> | <img width=740 src="https://static.igem.org/mediawiki/2017/a/a9/T--Munich--DetectionChip_Detection_Circuit.png"> | ||
Line 199: | Line 221: | ||
<img width=678 src="https://static.igem.org/mediawiki/2017/a/a4/T--Munich--Hardware_costvssensetivity.svg"> | <img width=678 src="https://static.igem.org/mediawiki/2017/a/a4/T--Munich--Hardware_costvssensetivity.svg"> | ||
<p> | <p> | ||
− | <b>Figure 5</b>: Cost vs. sensitivity diagram of several fluorescence detectors. We compared commercially available detectors (orange dots), low-cost detectors from publications<sup><a class="myLink" href="# | + | <b>Figure 5</b>: Cost vs. sensitivity diagram of several fluorescence detectors. We compared commercially available detectors (orange dots), low-cost detectors from publications<sup><a class="myLink" href="#ref_7">7-12</a></sup> (green dots) and detectors from other iGEM teams (blue dots) to our fluorescence detector (red dot). |
</p> | </p> | ||
</div> | </div> | ||
+ | <p> | ||
+ | Price is an important factor for the viability of any kind of diagnostic device. For these reason, we ran the calculations of the cost of a single CascAID reaction, assuming economy of scales could be use to produce a batch of 1000 reactions efficiently. According to our calculations, we come under the 1$ price, which was one of the requirements that we set for ourselves after our <a class="myLink" href="https://2017.igem.org/Team:Munich/HP/Gold_Integrated/Doctors_Without_Borders">interview with Dr. De La Tour from Doctors without Borders.</a> | ||
+ | </p> | ||
+ | <table class="myText" width="60%"> | ||
+ | <tbody><tr> | ||
+ | <th>Part</th> | ||
+ | <th>Cost</th> | ||
+ | <th>Fraction used/reaction</th> | ||
+ | <th>Cost/1000 ($)</th> | ||
+ | <th>Cost/1 ($)</th> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Cas13a protein purification</td> | ||
+ | <td>1448,95</td> | ||
+ | <td>2,54E-06</td> | ||
+ | <td>3,68</td> | ||
+ | <td>0,00368</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>1 NEB transcription kit</td> | ||
+ | <td>217</td> | ||
+ | <td>4,00E-07</td> | ||
+ | <td>0,0868</td> | ||
+ | <td>0,0000868</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>RPA kit</td> | ||
+ | <td>410</td> | ||
+ | <td>5,20E-04</td> | ||
+ | <td>213,54</td> | ||
+ | <td>0,21354</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>RNase alert</td> | ||
+ | <td>295</td> | ||
+ | <td>6,67E-05</td> | ||
+ | <td>19,67</td> | ||
+ | <td>0,01967</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>T7/RNTPs</td> | ||
+ | <td>67</td> | ||
+ | <td>2,40E-04</td> | ||
+ | <td>16,08</td> | ||
+ | <td>0,01608</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>RNase inhibitor</td> | ||
+ | <td>276</td> | ||
+ | <td>5,33E-04</td> | ||
+ | <td>147,2</td> | ||
+ | <td>0,1472</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>PDMS</td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td>0,1</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>glass fiber paper</td> | ||
+ | <td>0,5</td> | ||
+ | <td>0,002</td> | ||
+ | <td>1</td> | ||
+ | <td>0,001</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td><b>Lightbringer</b></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Geekreit Atmega 328p</td> | ||
+ | <td>2,92</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>2,92</td> | ||
+ | <td>0,00292</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>USB cable</td> | ||
+ | <td>3,49</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>3,49</td> | ||
+ | <td>0,00349</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>LDR GL5516 NT00183</td> | ||
+ | <td>0,17</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,17</td> | ||
+ | <td>0,00017</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Blue LED</td> | ||
+ | <td>0,12</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,12</td> | ||
+ | <td>0,00012</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Green LED</td> | ||
+ | <td>0,12</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,12</td> | ||
+ | <td>0,00012</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>BC635 transistor</td> | ||
+ | <td>0,14</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,14</td> | ||
+ | <td>0,00014</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Hole raster board</td> | ||
+ | <td>0,49</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,49</td> | ||
+ | <td>0,00049</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Resistors</td> | ||
+ | <td>0,56</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,56</td> | ||
+ | <td>0,00056</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>light filter foils</td> | ||
+ | <td>0,12</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>0,12</td> | ||
+ | <td>0,00012</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Neodym magnets</td> | ||
+ | <td>5,58</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>5,58</td> | ||
+ | <td>0,00558</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td><b>Plate</b></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>button red </td> | ||
+ | <td>23,65</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>23,65</td> | ||
+ | <td>0,02365</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>button green</td> | ||
+ | <td>23,65</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>23,65</td> | ||
+ | <td>0,02365</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>recessed socket</td> | ||
+ | <td>1,58</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>1,58</td> | ||
+ | <td>0,00158</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>U.S solid mini 12V 2 way valve</td> | ||
+ | <td>104,44</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>104,44</td> | ||
+ | <td>0,10444</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>valve connector</td> | ||
+ | <td>4,68</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>4,68</td> | ||
+ | <td>0,00468</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>chipboard</td> | ||
+ | <td>4,07</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>4,07</td> | ||
+ | <td>0,00407</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>ACa platte</td> | ||
+ | <td>10,34</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>10,34</td> | ||
+ | <td>0,01034</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Tygon tubing</td> | ||
+ | <td>27,88</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>27,88</td> | ||
+ | <td>0,02788</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Syringe 12 ml</td> | ||
+ | <td>6,42</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>6,42</td> | ||
+ | <td>0,00642</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Syringe vent</td> | ||
+ | <td>3,49</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>3,49</td> | ||
+ | <td>0,00349</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td><b>Heatbringer</b></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Peltier element</td> | ||
+ | <td>2,3</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>2,3</td> | ||
+ | <td>0,0023</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>pinboard</td> | ||
+ | <td>5,81</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>5,81</td> | ||
+ | <td>0,00581</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Thermosensor tmp006</td> | ||
+ | <td>8,13</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>8,13</td> | ||
+ | <td>0,00813</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Thermosensor si7021</td> | ||
+ | <td>9,29</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>9,29</td> | ||
+ | <td>0,00929</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Rasberry pi3b</td> | ||
+ | <td>40,66</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>40,66</td> | ||
+ | <td>0,04066</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td><b>Together for Hardware</b></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>jumper cable</td> | ||
+ | <td>1,74</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>1,74</td> | ||
+ | <td>0,00174</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>wires</td> | ||
+ | <td>6,39</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>6,39</td> | ||
+ | <td>0,00639</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>silicon blocks</td> | ||
+ | <td>27,3</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>27,3</td> | ||
+ | <td>0,0273</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>3d printed plastic (pla)</td> | ||
+ | <td>13,94</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>13,94</td> | ||
+ | <td>0,01394</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>M3 screws</td> | ||
+ | <td>2,9</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>2,9</td> | ||
+ | <td>0,0029</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>M3 screw-nuts</td> | ||
+ | <td>5,29</td> | ||
+ | <td>1,00E-03</td> | ||
+ | <td>5,29</td> | ||
+ | <td>0,00529</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td></td> | ||
+ | <td><b>0,85</b></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | </tr> | ||
+ | </tbody></table> | ||
+ | |||
<p> | <p> | ||
The detector is an excellent alternative to commercial fluorescence detectors. It is not limited to our specific application but can be used for the detection of any fluorescence signal in biological or chemical systems. We therefore think that our detector can benefit other iGEM teams and research groups that want to make fluorescence based detection fit for in-field applications. | The detector is an excellent alternative to commercial fluorescence detectors. It is not limited to our specific application but can be used for the detection of any fluorescence signal in biological or chemical systems. We therefore think that our detector can benefit other iGEM teams and research groups that want to make fluorescence based detection fit for in-field applications. | ||
Line 219: | Line 565: | ||
<li id="ref_6">Rissin, David M., et al. "Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations." Nature biotechnology 28.6 (2010): 595-599.</li> | <li id="ref_6">Rissin, David M., et al. "Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations." Nature biotechnology 28.6 (2010): 595-599.</li> | ||
+ | <li id="ref_7">Wu, Jing, et al. "An economical fluorescence detector for lab-on-a-chip devices with a light emitting photodiode and a low-cost avalanche photodiode." Analyst 137.2 (2012): 519-525.</li> | ||
+ | <li id="ref_8">Walczak, Rafał, and Krzysztof Adamski. "Inkjet 3D printing of microfluidic structures—on the selection of the printer towards printing your own microfluidic chips." Journal of Micromechanics and Microengineering 25.8 (2015): 085013.</li> | ||
+ | <li id="ref_9">Yang, Feng-Bo, et al. "A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement." Talanta 78.3 (2009): 1155-1158.0039-9140, https://doi.org/10.1016/j.talanta.2009.01.033.</li> | ||
+ | <li id="ref_10">Novak, Lukas, et al. "An integrated fluorescence detection system for lab-on-a-chip applications." Lab on a Chip 7.1 (2007): 27-29.</li> | ||
+ | <li id="ref_11">Pais, Andrea, et al. "High-sensitivity, disposable lab-on-a-chip with thin-film organic electronics for fluorescence detection." Lab on a Chip 8.5 (2008): 794-800.</li> | ||
+ | |||
</ol> | </ol> | ||
</p> | </p> |