(52 intermediate revisions by 4 users not shown) | |||
Line 79: | Line 79: | ||
<!-- Content Begin --> | <!-- Content Begin --> | ||
<img id="TopPicture" width="960" src="https://static.igem.org/mediawiki/2017/f/fc/T--Munich--FrontPagePicture_Hardware.jpg"> | <img id="TopPicture" width="960" src="https://static.igem.org/mediawiki/2017/f/fc/T--Munich--FrontPagePicture_Hardware.jpg"> | ||
+ | <div> | ||
+ | <img src="https://static.igem.org/mediawiki/2017/7/71/T--Munich--Prophecy.svg" height=50> | ||
+ | </div> | ||
+ | <audio controls> | ||
+ | <source src="https://static.igem.org/mediawiki/2017/8/87/Lightbringer_Prophecy.mp4" type="audio/mpeg"> | ||
+ | </audio> | ||
<table width="960" border=0 cellspacing=0 cellpadding=10> | <table width="960" border=0 cellspacing=0 cellpadding=10> | ||
<tr> | <tr> | ||
Line 89: | Line 95: | ||
</tr> | </tr> | ||
<tr><td colspan=6 align=left valign=center> | <tr><td colspan=6 align=left valign=center> | ||
− | <font size=7 color=#51a7f9><b style="color: #51a7f9">Fluorescence Detector</b></font> | + | <font size=7 color=#51a7f9><b style="color: #51a7f9">Fluorescence Detector (Lightbringer)</b></font> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 97: | Line 103: | ||
Our pathogen detection approach relies on Cas13a digesting RNA. A common way of monitoring RNase activities is using commercially available RNaseAlert, consisting of a fluorescent RNA beacon. This is impractical for in-field applications because commercial fluorescence detectors are expensive and inconveniently large. We therefore make our pathogen detection system fit for in-field applications by developing a cheap and handy fluorescence detector. Although many previous iGEM teams constructed fluorescence detectors, we could not find any that had a high enough sensitivity or the ability to measure fluorescence quantitatively. We therefore constructed a detector matching our requirements and compared it to others in a cost vs sensitivity diagram. | Our pathogen detection approach relies on Cas13a digesting RNA. A common way of monitoring RNase activities is using commercially available RNaseAlert, consisting of a fluorescent RNA beacon. This is impractical for in-field applications because commercial fluorescence detectors are expensive and inconveniently large. We therefore make our pathogen detection system fit for in-field applications by developing a cheap and handy fluorescence detector. Although many previous iGEM teams constructed fluorescence detectors, we could not find any that had a high enough sensitivity or the ability to measure fluorescence quantitatively. We therefore constructed a detector matching our requirements and compared it to others in a cost vs sensitivity diagram. | ||
</p> | </p> | ||
+ | |||
+ | <div class="captionPicture"> | ||
+ | <img width=678 src="https://static.igem.org/mediawiki/2017/a/a4/T--Munich--Hardware_costvssensetivity.svg"> | ||
+ | <p> | ||
+ | Cost vs. sensitivity diagram of several fluorescence detectors. We compared commercially available detectors (orange dots), low-cost detectors from publications<sup><a class="myLink" href="#ref_1">1-5</a></sup> (green dots) and detectors from other iGEM teams (blue dots) to our fluorescence detector (red dot). | ||
+ | </p> | ||
+ | </div> | ||
<p class="introduction"> | <p class="introduction"> | ||
− | Our detector is paper-based and can detect fluorescein concentrations down to | + | Our detector is paper-based and can detect fluorescein concentrations down to 100 nM. The detector is able to automatically |
measure fluorescence in units of equivalent fluorescein concentrations. It fits in a pipette box and costs less | measure fluorescence in units of equivalent fluorescein concentrations. It fits in a pipette box and costs less | ||
than 15 $. We were able to measure a time trace of Cas13a digesting RNaseAlert with our detector. For comparison | than 15 $. We were able to measure a time trace of Cas13a digesting RNaseAlert with our detector. For comparison | ||
Line 105: | Line 118: | ||
</p> | </p> | ||
<div class="captionPicture"> | <div class="captionPicture"> | ||
− | <img src="https://static.igem.org/mediawiki/2017/e/e2/T--Munich--Hardware_kinetic.png"> | + | <img id="sensitivity" src="https://static.igem.org/mediawiki/2017/e/e2/T--Munich--Hardware_kinetic.png"> |
<p> | <p> | ||
Time lapse measurement of Cas13a digesting RNaseAlert on paper using our detector. The | Time lapse measurement of Cas13a digesting RNaseAlert on paper using our detector. The | ||
Line 113: | Line 126: | ||
</div> | </div> | ||
<p class="introduction"> | <p class="introduction"> | ||
− | The time traces show an enzymatic reaction taking place on filter paper. This proves that our detector is sensitive | + | The time traces show an enzymatic reaction taking place on filter paper. For our experiments we used 185 nM RNaseAlert. By assuming that RNase A digested all RNaseAlert, we conclude that 185 nM of RNaseAlert have an equivalent fluorescence to 10 µM fluorescein. Our detection limit for RNaseAlert is therefore around 50 times lower which corresponds to a RNaseAlert concentration lower than 10 nM. This proves that our detector is sensitive |
enough and meets our requirements. However the detector is not limited to our specific application but can be used | enough and meets our requirements. However the detector is not limited to our specific application but can be used | ||
for the detection of any fluorescence signal in biological or chemical systems. We therefore think that our detector | for the detection of any fluorescence signal in biological or chemical systems. We therefore think that our detector | ||
Line 139: | Line 152: | ||
<img width = 900 src=https://static.igem.org/mediawiki/2017/7/70/T--Munich--Hardware_katzioveralldesign.svg> | <img width = 900 src=https://static.igem.org/mediawiki/2017/7/70/T--Munich--Hardware_katzioveralldesign.svg> | ||
<p> | <p> | ||
− | + | Schematic drawing of our fluorescence detector. Light rays with a certain wavelength are displayed as arrows with corresponding color. The most important electronic components are displayed as their circuit symbol. | |
</p> | </p> | ||
</div> | </div> | ||
Line 167: | Line 180: | ||
<div class="equationDiv"><img src="https://static.igem.org/mediawiki/2017/3/33/T--Munich--Hardware_equation1.png"><span>(1)</span></div> | <div class="equationDiv"><img src="https://static.igem.org/mediawiki/2017/3/33/T--Munich--Hardware_equation1.png"><span>(1)</span></div> | ||
<p> | <p> | ||
− | where | + | where γ is a parameter depending on the type of resistor being used and can even differ for LDRs with the same type |
designation. | designation. | ||
</p> | </p> | ||
Line 176: | Line 189: | ||
<p> | <p> | ||
which is given in the data sheet of the LDR. The denominator is the decadic logarithm of the fraction of two light | which is given in the data sheet of the LDR. The denominator is the decadic logarithm of the fraction of two light | ||
− | intensities of 100 Lx and 10 Lx. <i>R<sub>10</sub></i> and <i>R<sub>100</sub></i> are the corresponding resistances at these light intensities. The used resistor with the type designation GL5516 NT00183 has a parameter | + | intensities of 100 Lx and 10 Lx. <i>R<sub>10</sub></i> and <i>R<sub>100</sub></i> are the corresponding resistances at these light intensities. The used resistor with the type designation GL5516 NT00183 has a parameter γ of 0.8. |
</p> | </p> | ||
<p> | <p> | ||
− | The response of a LDR depends on the wavelength | + | The response of a LDR depends on the wavelength λ of the incoming light. The data sheet provides information on |
the relative response normalized to the maximal response. The relative response is maximum for a wavelength of 540 | the relative response normalized to the maximal response. The relative response is maximum for a wavelength of 540 | ||
nm and is therefore appropriate for detection of green fluorophores. | nm and is therefore appropriate for detection of green fluorophores. | ||
Line 220: | Line 233: | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/3/3f/T--Munich--Hardware_equation6.png"><span>(6)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/3/3f/T--Munich--Hardware_equation6.png"><span>(6)</span></div> | ||
<p> | <p> | ||
− | The change | + | The change ∆<i>U<sub>LDR</sub></i> of <i>U<sub>LDR</sub></i> between a maximum value <i>R<sub>max</sub></i> and a minimum value <i>R<sub>min</sub></i> of <i>R<sub>LDR</sub></i> is |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/9/9b/T--Munich--Hardware_equation7.png"><span>(7)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/9/9b/T--Munich--Hardware_equation7.png"><span>(7)</span></div> | ||
Line 228: | Line 241: | ||
<div class="equationDiv"><img src="https://static.igem.org/mediawiki/2017/c/c0/T--Munich--Hardware_equation8.png"><span>(8)</span></div> | <div class="equationDiv"><img src="https://static.igem.org/mediawiki/2017/c/c0/T--Munich--Hardware_equation8.png"><span>(8)</span></div> | ||
<p> | <p> | ||
− | We expect an <i>R<sub>max</sub></i> of approximately 2 | + | We expect an <i>R<sub>max</sub></i> of approximately 2 MΩ and an <i>R<sub>min</sub></i> of approximately 1 MΩ. By using <a href="#equation8">equation 8</a> as a guideline we choose <i>R<sub>ref</sub></i> to be 1.5 MΩ. |
</p> | </p> | ||
</td> | </td> | ||
Line 255: | Line 268: | ||
<h4>Control Circuit for the LED</h4> | <h4>Control Circuit for the LED</h4> | ||
<p> | <p> | ||
− | The digital output pin is connected to the base of the transistor via a voltage divider, consisting of the resistor <i>R<sub>1</sub></i> with a resistance of 1 | + | The digital output pin is connected to the base of the transistor via a voltage divider, consisting of the resistor <i>R<sub>1</sub></i> with a resistance of 1 kΩ and the resistor <i>R<sub>2</sub></i> with a resistance of 9.1 kΩ. When the output pin is set to 5 V a voltage of 4.5 V is present at the base of the transistor. This is above the base-emitter-on voltage and the LED is turned on. |
− | The resistor <i>R<sub>3</sub></i> with resistance 39 | + | The resistor <i>R<sub>3</sub></i> with resistance 39 Ω was chosen empirically to limit the LEDs working current and to power it at |
maximum brightness. The control circuit is illustrated in the image below. | maximum brightness. The control circuit is illustrated in the image below. | ||
</p> | </p> | ||
Line 286: | Line 299: | ||
<p> | <p> | ||
Transmission spectra of the chosen filter foils of our detector. The transmission spectra for the | Transmission spectra of the chosen filter foils of our detector. The transmission spectra for the | ||
− | orange filter foil(orange graph) has nearly no overlap with the transmission spectra of the blue filter foil(blue graph). | + | orange filter foil (orange graph) has nearly no overlap with the transmission spectra of the blue filter foil (blue graph). |
− | The transmission spectra of two blue and one filter foil(black graph) is therefore nearly 0 up to 700 nm. | + | The transmission spectra of two blue and one filter foil (black graph) is therefore nearly 0 up to 700 nm. |
</p> | </p> | ||
</div> | </div> | ||
Line 306: | Line 319: | ||
<h4>3D Printed Parts</h4> | <h4>3D Printed Parts</h4> | ||
<p> | <p> | ||
− | We intended to put the LED,the fluorescence sample and the LDR in direct proximity, to ensures a maximum use | + | We intended to put the LED, the fluorescence sample and the LDR in direct proximity, to ensures a maximum use |
of excitation light and emission light. We therefore chose a sandwich-like design for our sample holder that can be | of excitation light and emission light. We therefore chose a sandwich-like design for our sample holder that can be | ||
placed into a slot where the detection system snaps in and keeps the sample in position. | placed into a slot where the detection system snaps in and keeps the sample in position. | ||
Line 316: | Line 329: | ||
the detection windows because tape is usually autofluorescent and causes a high background signal. A piece of filter | the detection windows because tape is usually autofluorescent and causes a high background signal. A piece of filter | ||
paper is placed between the two halves of the sandwich. The upper and lower part of this sandwich are pressed | paper is placed between the two halves of the sandwich. The upper and lower part of this sandwich are pressed | ||
− | together with magnets to hold the filter paper in position and ensure an user-friendly exchange of filter papers. An | + | together with magnets to hold the filter paper in position and ensure an user-friendly exchange of filter papers. We also designed a <a class="myLink" href="https://2017.igem.org/Team:Munich/Hardware/Paperstrip">paper strip</a> that matches our sample holder, to provide a low-cost and durable platform to store a reaction mix. An |
explosion drawing of the sample holder is shown in the figure below. | explosion drawing of the sample holder is shown in the figure below. | ||
</p> | </p> | ||
Line 329: | Line 342: | ||
<p> | <p> | ||
The sandwich can now be inserted into the slot of the detection device. The LED and the LDR are mounted onto | The sandwich can now be inserted into the slot of the detection device. The LED and the LDR are mounted onto | ||
− | beams at opposite | + | beams at opposite sides of the detection device. The sandwich snaps in when the LED and the LDR are at the right |
position under the excitation and over detection window. Four magnets apply an additional force to the beams and | position under the excitation and over detection window. Four magnets apply an additional force to the beams and | ||
press the LED and the LDR close together. This design ensures that the distance between filter paper, LED and | press the LED and the LDR close together. This design ensures that the distance between filter paper, LED and | ||
Line 337: | Line 350: | ||
<img src="https://static.igem.org/mediawiki/2017/3/32/T--Munich--Hardware_explodetdetectiondev.svg" width="700"> | <img src="https://static.igem.org/mediawiki/2017/3/32/T--Munich--Hardware_explodetdetectiondev.svg" width="700"> | ||
<p> | <p> | ||
− | Explosion drawing of detection slot. | + | Explosion drawing of the detection slot. |
</p> | </p> | ||
</div> | </div> | ||
Line 348: | Line 361: | ||
<tr class="lastRow"><td colspan=6 align=center valign=center> | <tr class="lastRow"><td colspan=6 align=center valign=center> | ||
− | <h4>List of Materials and Cost Calculation</h4> | + | <h4 id="cost">List of Materials and Cost Calculation</h4> |
<table class="myTable" width=60%> | <table class="myTable" width=60%> | ||
<th class="leftAligned">Used item</th> | <th class="leftAligned">Used item</th> | ||
Line 414: | Line 427: | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | |||
+ | |||
<tr class="lastRow"><td colspan=6 align=center valign=center> | <tr class="lastRow"><td colspan=6 align=center valign=center> | ||
Line 447: | Line 462: | ||
<p> | <p> | ||
where <i>k</i> is a constant that depends on the transmission spectra of the filter foils, the spectra of the fluorophore, the | where <i>k</i> is a constant that depends on the transmission spectra of the filter foils, the spectra of the fluorophore, the | ||
− | spectra of the LED and light scattering effects of the filter paper,but not on <i>I<sub>0</sub></i>. <i>k</i> can be assumed to be constant for one specific measurement set-up. | + | spectra of the LED and light scattering effects of the filter paper, but not on <i>I<sub>0</sub></i>. <i>k</i> can be assumed to be constant for one specific measurement set-up. |
</p> | </p> | ||
<p id="equation16"> | <p id="equation16"> | ||
Line 466: | Line 481: | ||
</p> | </p> | ||
<p> | <p> | ||
− | We therefore prepared 10-fold dilutions from 100 nM to 1 mM. For each measurement we pipetted 30 µl of sample on | + | We therefore prepared 10-fold dilutions of fluorescein from 100 nM to 1 mM. For each measurement we pipetted 30 µl of sample on |
a fresh filter paper, placed it in the detector and turned on the LED. We measured the resistance <i>R<sub>LDR</sub></i> directly with a multimeter. After each measurement the detector was cleaned gently with ethanol. The first and last measurement | a fresh filter paper, placed it in the detector and turned on the LED. We measured the resistance <i>R<sub>LDR</sub></i> directly with a multimeter. After each measurement the detector was cleaned gently with ethanol. The first and last measurement | ||
− | of each series | + | of each series were conducted with plain water to determine <i>R<sub>b</sub></i> and to confirm the absence of contaminations. A plot of the normalized resistances is shown in the figure below. We fitted the data with <a id="equation16">equation 16</a> to determine a value for <i>k</i> using a value of 0.8 for <i>γ</i> gives |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d4/T--Munich--Hardware_equation17.png"><span>(17)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d4/T--Munich--Hardware_equation17.png"><span>(17)</span></div> | ||
Line 479: | Line 494: | ||
</div> | </div> | ||
<p> | <p> | ||
− | To determine that <i>k</i> does not depend on the intensity <i>I<sub>0</sub></i> we made two measurement series. We changed the resistance <i>R<sub>3</sub></i> in series to the LED to dim the light Intensity <i>I<sub>0</sub></i>. We used a 39 | + | To determine that <i>k</i> does not depend on the intensity <i>I<sub>0</sub></i> we made two measurement series. We changed the resistance <i>R<sub>3</sub></i> in series to the LED to dim the light Intensity <i>I<sub>0</sub></i>. We used a 39 Ω resistor and a 60 Ω resistor. For the set-up with the 39 Ω resistor we additionally measured a 200 nM sample because this is the expected final working condition of the detector. |
</p> | </p> | ||
</td> | </td> | ||
Line 495: | Line 510: | ||
</p> | </p> | ||
<p> | <p> | ||
− | As a first step the exact value of the supply voltage <i>U<sub>0</sub></i> needs to be measured. The supply voltage is connected via an additional voltage divider with an analog pin. The voltage divider consists of a 100 | + | As a first step the exact value of the supply voltage <i>U<sub>0</sub></i> needs to be measured. The supply voltage is connected via an additional voltage divider with an analog pin. The voltage divider consists of a 100 Ω resistor and a 910 kΩ resistor. The analog pin measures still a correct value for the supply voltage <i>U<sub>0</sub></i> because the first resistor is negligible small compared to the second resistor. We did not connect the analog pin directly with the power supply to prevent the micro controller from damage in case of a short circuit or a peak voltage caused by an other component of the overall device. The micro controller measures the supply voltage 50 times with a delay time of 50 ms between measurements. |
− | compared to the second resistor. We did not connect the analog pin directly with the power supply to prevent the | + | It calculates the average of <i>U<sub>0</sub></i> and the relative standard error <i>σ<sub>U0</sub></i> |
− | micro controller from damage in case of a short circuit or a peak voltage caused by an other component of the overall | + | |
− | device. The micro controller measures the supply voltage 50 times with a delay time of 50 ms between measurements. | + | |
− | It calculates the average of <i>U<sub>0</sub></i> and the relative | + | |
, which is used as measurement | , which is used as measurement | ||
uncertainty for further calculations. | uncertainty for further calculations. | ||
Line 508: | Line 520: | ||
a waiting time of 30 s the actual measurement starts. This waiting time was determined empirically and is required | a waiting time of 30 s the actual measurement starts. This waiting time was determined empirically and is required | ||
because of the slow response of the LDR. <i>U<sub>LDR</sub></i> is measured in the same way as <i>U<sub>0</sub></i>. The average of <i>U<sub>LDR</sub></i> and the | because of the slow response of the LDR. <i>U<sub>LDR</sub></i> is measured in the same way as <i>U<sub>0</sub></i>. The average of <i>U<sub>LDR</sub></i> and the | ||
− | relative | + | relative standard error <i>σ<sub>ULDR</sub></i> are calculated. Equation 5 is used to calculate <i>R<sub>LDR</sub></i> from the average |
of <i>U<sub>LDR</sub></i>. We derived an equation for the propagation of the relative systematic and the relative statistical uncertainty | of <i>U<sub>LDR</sub></i>. We derived an equation for the propagation of the relative systematic and the relative statistical uncertainty | ||
− | of <i>U<sub>0</sub></i> and <i>U<sub>LDR</sub></i>. For the relative statistical uncertainty <i> | + | of <i>U<sub>0</sub></i> and <i>U<sub>LDR</sub></i>. For the relative statistical uncertainty <i>σ<sub>stat</sub></i> of <i>R<sub>LDR</sub></i> we get |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/e/e9/T--Munich--Hardware_equation18.png"><span>(18)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/e/e9/T--Munich--Hardware_equation18.png"><span>(18)</span></div> | ||
<p> | <p> | ||
We used a value of 1 digit for the absolute systematic uncertainty for a voltage measurement. The relative systematic | We used a value of 1 digit for the absolute systematic uncertainty for a voltage measurement. The relative systematic | ||
− | uncertainty is 1/U for a measured voltage U. For the relative systematic uncertainty <i> | + | uncertainty is 1/U for a measured voltage U. For the relative systematic uncertainty <i>σ<sub>sys</sub></i> of <i>R<sub>LDR</sub></i> we therefore get |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/0/09/T--Munich--Hardware_equation19.png"><span>(19)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/0/09/T--Munich--Hardware_equation19.png"><span>(19)</span></div> | ||
<p> | <p> | ||
− | The equation for the total uncertainty <i> | + | The equation for the total uncertainty <i>σ<sub>RLDR</sub></i> is then |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d8/T--Munich--Hardware_equation20.png"><span>(20)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d8/T--Munich--Hardware_equation20.png"><span>(20)</span></div> | ||
<p> | <p> | ||
− | <i>R<sub>LDR</sub><i>, <i>R<sub>b</sub><i> and their uncertainties are calculated by the micro controller, read by the computer and saved for further analysis in a text file. | + | <i>R<sub>LDR</sub></i>, <i>R<sub>b</sub></i> and their uncertainties are calculated by the micro controller, read by the computer and saved for further analysis in a text file. |
</p> | </p> | ||
</td> | </td> | ||
Line 537: | Line 549: | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/a/a3/T--Munich--Hardware_equation21.png"><span>(21)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/a/a3/T--Munich--Hardware_equation21.png"><span>(21)</span></div> | ||
<p> | <p> | ||
− | The equation for the relative uncertainty <i> | + | The equation for the relative uncertainty <i>σ<sub>c</sub></i> of the fluorescein concentration <i>c</i> is |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/c/c3/T--Munich--Hardware_equation22.png"><span>(22)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/c/c3/T--Munich--Hardware_equation22.png"><span>(22)</span></div> | ||
<p> | <p> | ||
− | where <i> | + | where <i>σ<sub>k</sub></i> is the relative uncertainty from the fit of <i>k</i>. We are now enabled to measure fluorescence in units of equivalent fluorescein concentrations <i>c</i>. We analysed data of a first experiment with these equations. The resulting figure is shown in the beginning of this documentation. |
</p> | </p> | ||
<p> | <p> | ||
− | With these quantitative data it is now an easy task to verify if the collateral RNase-activity of Cas13a got activated by | + | With these quantitative data it is now an easy task to verify if the collateral RNase-activity of Cas13a got activated by the binding of target RNA. For the convenience of the end user we choose to extract two kinds of information from the time traces produced with our detector. |
− | We check if | + | We check if an enzymatic reaction has taken place on the filter paper by evaluating whether the first 5 data points show a monotonous rise. Additionally we check if a threshold of 3 µM equivalent fluorescein concentration was crossed by looking at the last 3 data points. |
− | + | These two informations are computed in the following way: | |
− | if the reaction has taken place and the threshold was crossed the detector software will | + | if the reaction has taken place and the threshold was crossed, the detector software will show a plus, meaning "Pathogen detected"; if the reaction has not taken place but the threshold was crossed, the detector software will show a minus, meaning "Pathogen not detected". |
− | The other two combinations will lead to the | + | The other two combinations will also lead to the minus. |
− | The software will also create a graph similar to the graph in the beginning of this documentation to provide a deeper insight for the | + | The software will also create a graph similar to the graph in the beginning of this documentation to provide a deeper insight for the end user if needed. The software was written in Java, using the library for interfacing with the Arduino micro-controller. Right now it is optimized for Windows, but we plan on expanding it to more platforms. The code can be found on <a class="myLink" href="https://github.com/igemsoftware2017/igem_munich_2017">our github page.</a> |
</p> | </p> | ||
<p> | <p> | ||
− | We think that our detector is a more reliable read out system compared to other possibilities because | + | We think that our detector is a more reliable read out system compared to other possibilities, because Lightbringer provides deep insight into the reaction dynamics. Hence with an exact knowledge of Cas13a's reaction kinetics and further analytic tools, a nearly fail-safe read out can be achieved. |
− | + | A colorimetric readout, a binary change of color, in contrast, is way more primitive and provides no insight into any dynamics. | |
− | A colorimetric readout, a change | + | |
</p> | </p> | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | <tr><td colspan=6 align=center valign=center> | ||
+ | <h3>References</h3> | ||
+ | <p> | ||
+ | <ol style="text-align: left"> | ||
+ | <li id="ref_1">Wu, Jing, et al. "An economical fluorescence detector for lab-on-a-chip devices with a light emitting photodiode and a low-cost avalanche photodiode." Analyst 137.2 (2012): 519-525.</li> | ||
+ | <li id="ref_2">Walczak, Rafał, and Krzysztof Adamski. "Inkjet 3D printing of microfluidic structures—on the selection of the printer towards printing your own microfluidic chips." Journal of Micromechanics and Microengineering 25.8 (2015): 085013.</li> | ||
+ | <li id="ref_3">Yang, Feng-Bo, et al. "A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement." Talanta 78.3 (2009): 1155-1158.0039-9140, https://doi.org/10.1016/j.talanta.2009.01.033.</li> | ||
+ | <li id="ref_4">Novak, Lukas, et al. "An integrated fluorescence detection system for lab-on-a-chip applications." Lab on a Chip 7.1 (2007): 27-29.</li> | ||
+ | <li id="ref_5">Pais, Andrea, et al. "High-sensitivity, disposable lab-on-a-chip with thin-film organic electronics for fluorescence detection." Lab on a Chip 8.5 (2008): 794-800.</li> | ||
+ | |||
+ | </ol> | ||
+ | </p> | ||
+ | </td> | ||
+ | </tr> | ||
Latest revision as of 22:37, 15 December 2017
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|