Line 137: | Line 137: | ||
</p> | </p> | ||
<p> | <p> | ||
− | The relative uncertainty | + | The relative uncertainty <i>σ<sub>RLDR</sub></i> _R_LDR of <i>R<sub>LDR</sub></i> can be calculated with |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d8/T--Munich--Hardware_equation20.png"><span>(3)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d8/T--Munich--Hardware_equation20.png"><span>(3)</span></div> | ||
Line 145: | Line 145: | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/f/f7/T--Munich--Hardware_equation16.png"><span>(4)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/f/f7/T--Munich--Hardware_equation16.png"><span>(4)</span></div> | ||
<p> | <p> | ||
− | where | + | where <i>R<sub>b</sub></i> is the resistance measured for plain water, <i>γ</i> is a parameter depending on the type of LDR used and <i>c</i> is the fluorescein concentration. <i>k</i> is the fit parameter and is a constant for a measurement set up. |
</p> | </p> | ||
<p> | <p> | ||
− | Fitting the data for | + | Fitting the data for <i>γ</i> = 0.8 gives |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d4/T--Munich--Hardware_equation17.png"><span>(5)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/d/d4/T--Munich--Hardware_equation17.png"><span>(5)</span></div> | ||
Line 162: | Line 162: | ||
</div> | </div> | ||
<p> | <p> | ||
− | We are now able to measure fluorescence in equivalent fluorescein concentrations c. Equation … solved for c is | + | We are now able to measure fluorescence in equivalent fluorescein concentrations <i>c</i>. Equation … solved for <i>c</i> is |
</p> | </p> | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/a/a3/T--Munich--Hardware_equation21.png"><span>(6)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/a/a3/T--Munich--Hardware_equation21.png"><span>(6)</span></div> | ||
Line 171: | Line 171: | ||
<div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/c/c3/T--Munich--Hardware_equation22.png"><span>(7)</span></div> | <div class="equationDiv"><img class="largeEquation" src="https://static.igem.org/mediawiki/2017/c/c3/T--Munich--Hardware_equation22.png"><span>(7)</span></div> | ||
<p> | <p> | ||
− | where | + | where <i>σ<sub>Rb</sub></i> is the relative uncertainty of <i>R<sub>b</sub></i> and <i>σ<sub>k</sub></i> is the relative uncertainty of <i>k</i> given by the result from the fit of <i>k</i>. |
</p> | </p> | ||
<p> | <p> |