Difference between revisions of "Team:BIT/Demonstrate/Bio-amplifier"

Line 38: Line 38:
 
<body>
 
<body>
 
 
<div class="fh5co-loader"></div>
+
<div class="fh5co-loader"></div>
 
 
 
<div id="page">
 
<div id="page">
Line 53: Line 53:
 
 
 
<li class="has-dropdown">
 
<li class="has-dropdown">
<a style="color:#1b8fac">Project</a>
+
<a>Project</a>
 
<ul class="dropdown">
 
<ul class="dropdown">
 
<li><a href="https://2017.igem.org/Team:BIT/Design">Design</a></li>
 
<li><a href="https://2017.igem.org/Team:BIT/Design">Design</a></li>
Line 93: Line 93:
 
<li><a href="https://2017.igem.org/Team:BIT/Collarbration">Collaborations</a></li>
 
<li><a href="https://2017.igem.org/Team:BIT/Collarbration">Collaborations</a></li>
 
<li><a href="https://2017.igem.org/Team:BIT/Team/Member">Member</a></li>
 
<li><a href="https://2017.igem.org/Team:BIT/Team/Member">Member</a></li>
<li><a href="https://2017.igem.org/Team:BIT/Team/Attribution">Attribution</a></li>
+
<li><a href="https://2017.igem.org/Team:BIT/Attributions">Attributions</a></li>
 
</ul>
 
</ul>
 
</li>
 
</li>

Revision as of 15:31, 1 November 2017

Necessity of E.coli ΔLysA

  After we have verified that lysine can be the signal upstream the sensor, what we need to do next is to conform the connection between the lysine concentration and the growth of E.coli ΔLysA. Before that, we have to make sure that the growth of wild type E.coli has no connection with lysine concentration. Part BBa_K876070 was transformed into wild type E.coli to test its OD600 and GFP fluorescence every hour with microplate reader. Lysine was added in increments of 0.5ug/mL to establish a range of 0-3ug/mL. It shows that the growth of wild type E.coli has no connection with lysine concentration. From this, we can say that it’s necessary for E.coli ΔLysA to be the signal receiver of lysine.

Confirmation in Models

  After we have confirmed that the E.coli ΔLysA can response and transform lysine signal to the fluorescent signal, what we need to do is to amplify the fluorescent signal and improve the sensitivity. To solve this problem and make sure that our own-designed circuit works well, we need to test the effect of the strong promoter, cyclic amplifier and dual fluorescence system respectively. The verified experiments are as follows.

1.Strong Promoter

  To confirm that the strong constitutive promoter can induce plux promoter, we designed the biobrick BBa_K2305004. The purpose of this biobrick is to produce as much green fluorescence as possible by inducing the induced promoter plux, to ensure a stronger expression in E.coli.

Free HTML5 Bootstrap Template

 We added a strong promoter on the basis of the previous part BBa_J37032. Parts from BBa_J23100 to BBa_J23119 are a family of constitutive promoter parts isolated from a small combinatorial library. With the addition of the strong constitutive promoter upstream the plux, we hope the plux promoter can be induced and therefore express more GFP. As the figure shows, in the first eight hours the OD600 value grew well, and the new part reached a higher GFP expression in E.coli than the previous part. Importantly, the new part has amplified the expression of GFP for more than 10 times. So we can say that with the existence of the strong constitutive promoter, the expression of GFP has been amplified. So it’s effective for us to put plux promoter upstream the route, in other to amplify the detecting signal.

2.Cyclic Amplifier

Free HTML5 Bootstrap Template

  The luxI downstream the induced promoter plux will be encoded to produce LuxI, which can combine with LuxR to promote plux. It can be used to form a positive feedback, so that the input signal can be further amplified.
  In order to verify the effect of the cyclic amplifier on the fluorescent signal, we designed two gene circuits. Without luxI, BBa_K2305005 cannot produce LuxI, so it can not constitute a cyclic amplifier. But BBa_K2305016 can do it, then we compare these two gene circuits to verify the cyclic amplifier.

Free HTML5 Bootstrap Template
Free HTML5 Bootstrap Template

  The results of the validation show that the GFP fluorescence of BBa_K2305005 did not change over time. The fluorescence intensity of BBa_K2305016 remarkably increased over time, and the growth rate has increased after seventh hours later. Therefore, it can be shown that the expression of GFP protein, as significantly increased after the addition of the cyclic amplifier, which will have a greater effect on our detection.

3.Dual Fluorescence System

  We inserted the lacl gene into the downstream of the plux gene. LacI can inhibit the expression of the plac promoter to inhibit the expression of the RFP gene, a reporter downstream the plac promoter. Because of the existence of the strong promoter and the cyclic amplifier, the expression and the fluorescence intensity of the GFP will increase along with the growth of the E.coli ΔLysA, which is promoted by lysine. On the contrary, the expression and the fluorescence intensity of the RFP are inhibited. Then we used the GFP /RFP fluorescence intensity ratio to represent the output signal to improve the sensitivity.

Free HTML5 Bootstrap Template
Free HTML5 Bootstrap Template

  To test the effect of the dual reporter fluorescence, the genetic circuits we designed are as shown. The pbad is a promoter induced by L-arabinose. We simulate the response of E.coli ΔLysA to the lysine concentration with the response of pbad promoter to the L-arabinose concentration. With the increase of the lysine concentration, the transcriptional efficiency of the pbad increases, therefore the expression of the lacl and GFP will also increase. On the contrary, the expression of RFP is low, because LacI can inhibit the plac promoter. Then we use the GFP /RFP fluorescence intensity ratio to represent the concentration of the L-arabinose. And we have worked out the relationship of the GFP expression of BBa_K584000 and the L-arabinose concentration, as well as the connection between the fluorescence ratio of the BBa_K2305002 and the L-arabinose concentration, in order to verify that the dual reporter fluorescence can improve the sensitivity of our detection.

Hire Us!

Facilis ipsum reprehenderit nemo molestias. Aut cum mollitia reprehenderit. Eos cumque dicta adipisci architecto culpa amet.

Contact Us