Difference between revisions of "Team:Aix-Marseille/InterLab"

Line 9: Line 9:
 
==Materials and Methods:==
 
==Materials and Methods:==
  
==Used plasmids===
+
=Used plasmids=
  
 
Devices from Interlab Measurement Kit
 
Devices from Interlab Measurement Kit
Line 21: Line 21:
 
#Test Device 6:J23117+I13504
 
#Test Device 6:J23117+I13504
  
==Used strain==
+
=Used strain=
  
 
E. coli E5alpha  
 
E. coli E5alpha  
  
==Used material==
+
=Used material=
  
 
1ml LUDOX
 
1ml LUDOX
Line 40: Line 40:
 
Pipettes
 
Pipettes
  
==Used machines==
+
=Used machines=
  
 
#Tecan's Infinite®  
 
#Tecan's Infinite®  
 
#Confocal microscope
 
#Confocal microscope
  
==Used software==
+
=Used software=
  
 
Link protocoles
 
Link protocoles
Line 51: Line 51:
 
[[File:T--Aix-Marseille--fluo interlab.jpeg]]
 
[[File:T--Aix-Marseille--fluo interlab.jpeg]]
  
==Protocol description==
+
=Protocol description=
  
 
[[File:T--Aix-Marseille--fluoresceincurve.jpeg|500px|right]]
 
[[File:T--Aix-Marseille--fluoresceincurve.jpeg|500px|right]]

Revision as of 09:08, 24 October 2017

InterLab

How close can the numbers be when fluorescence is measured all around the world ?

Gfp Fluorescence of E.coli

In order to support the interlab approach, our team participate to the Fourth International InterLab Measurement Study. We are glad to contribute to this studie based on reliable and repeatable measurement. The challenge this year consist in etablishing a GFP measurement protocol that can be used produce comparable GFP measurements on plate readers. Furthermore, teams are also going to test some RBS devices that are intended to make gene expression more precise and reliable.

Materials and Methods:

Used plasmids

Devices from Interlab Measurement Kit

  1. Positive control
  2. Negative control
  3. Test Device 1:J23101.BCD2.E0040.B0015
  4. Test Device 2:J23106.BCD2.E0040.B0015
  5. Test Device 3:J23117.BCD2.E0040.B0015
  6. Test Device 4:J23101+I13504
  7. Test Device 5:J23106+I13504
  8. Test Device 6:J23117+I13504

Used strain

E. coli E5alpha

Used material

1ml LUDOX H20 96 well plate,black with flat bottom fluorescein 10ml 1xPBS LB (Luria Bertani) media Chloramphenicol (stock concentration 25mg/mL dissolved in EtOh - working stock 25 ug/ml) 50 ml Falcon tube Incubator at 37°C 1.5 ml eppendorf tube Ice bucket Pipettes

Used machines

  1. Tecan's Infinite®
  2. Confocal microscope

Used software

Link protocoles

T--Aix-Marseille--fluo interlab.jpeg

Protocol description

T--Aix-Marseille--fluoresceincurve.jpeg

We used plasmids containing different promoter from the 2017 distribution kit and transfected them into E.coli. Before measuring fluorescence expression, we used LUDOX and fluorescein to calibrate the TECAN. We prepared a dilution series of fluorescein in 4 duplicates and measure the fluorescence in a 96 well plate in a plate reader. By measuring these in all standard modes, we generated a standard curve of fluorescence for fluorescein concentration. We used this to correct cell based readings to an equivalent fluorescein concentration and convert this into a concentration of GFP.

Results

T--Aix-Marseille--fluorescencecourberesultats.jpeg


T--Aix-Marseille--OD600fluo.jpeg


T--Aix-Marseille--fluoOD600.jpeg