Line 166: | Line 166: | ||
<div id="backgroundimage1"><div class="background-gradient-down"><p class="wide-heading-type mainwrap align-center">OUR TEAM</p></div></div> | <div id="backgroundimage1"><div class="background-gradient-down"><p class="wide-heading-type mainwrap align-center">OUR TEAM</p></div></div> | ||
<div id="panel1"> | <div id="panel1"> | ||
− | <p class="body-type mainwrap">Below is an interactive list of the laboratory techniques employed by the team. Click to | + | <p class="body-type mainwrap">Below is an interactive list of the laboratory techniques employed by the team. Click to navigate to that protocol</p> |
+ | <ul class="wide-heading-type"> | ||
+ | <li><a href="KODPCR">KOD PCR</a></li> | ||
+ | <li><a href="ColonyPCR">Colony PCR</a></li> | ||
+ | </ul> | ||
<div id="protocol-accordion"class="mainwrap"> | <div id="protocol-accordion"class="mainwrap"> | ||
− | <h3 class="inline-heading-type"> | + | <a name="KODPCR"></a> |
+ | <h3 class="inline-heading-type">KOD PCR</h3> | ||
<div> | <div> | ||
<p class="body-type"> | <p class="body-type"> | ||
Line 211: | Line 216: | ||
</table> | </table> | ||
</div> | </div> | ||
+ | <a name="ColonyPCR"></a> | ||
<h3 class="inline-heading-type">Colony PCR</h3> | <h3 class="inline-heading-type">Colony PCR</h3> | ||
<div> | <div> |
Revision as of 16:27, 28 October 2017
OUR TEAM
Below is an interactive list of the laboratory techniques employed by the team. Click to navigate to that protocol
KOD PCR
Materials
- 5% DMSO
- 2x KOD Hot Start Master Mix
- PCR Tubes
- Forward Primers(s) [10 uM]
- Reverse Primer(s) [10 uM]
- DNA Template
- Deionized water
Procedure
- Add 18.5 uL of deionized water to PCR tube
- Add 1.5 µl of both the requisite Forward and Reverse Primers to PCR tube
- Add 1 ul of DNA template
- Add 27.5 µl of KOD Hot start Master Mix to PCR tube
- Centrifuge for 10 seconds to remove air bubbles
- Place in Thermocycler
Thermocycler Conditions
Number of Cycles | From 20 - 40 |
---|---|
Annealing Temperature | Set temperature to the lowest primer melt temperature |
Extension Time | If target size is: < 500 bp run 10 sec/kb 500-1000 bp run 15 sec/kb 1000-3000 bp run 20 sec/kb < 3000 bp run 20 sec/kb |
Colony PCR
Materials
- 5% DMSO
- 2x KOD Hot Start Master Mix
- PCR Tubes
- Forward Primers(s) [10 uM]
- Reverse Primer(s) [10 uM]
- DNA Template
- Deionized water
Procedure
- Prepare the DNA template by picking a colony from a plate and mixing it into 10 uL of deionized water in a PCR tube
- Add 17.5 µl of deionized water to another PCR tube
- Add 1.5 µl of both the requisite Forward and Reverse Primers to the second PCR tube
- Add 2 ul of water containing cells with DNA template sample
- Add 27.5 µl of KOD Hot Start Master Mix
- Centrifuge for 10 seconds to remove air bubbles
- Place in Thermocycler
Thermocycler Conditions
Number of Cycles | From 20 - 40 |
---|---|
Annealing Temperature | Set temperature to the lowest primer melt temperature |
Extension Time | If target size is: < 500 bp run 10 sec/kb 500-1000 bp run 15 sec/kb 1000-3000 bp run 20 sec/kb < 3000 bp run 20 sec/kb |
Overlap Extension PCR
Materials
- 5% DMSO
- 2x KOD Hot Start Master Mix
- PCR Tubes
- Forward Primers(s) [10 uM]
- Reverse Primer(s) [10 uM]
- DNA Template
- Deionized water
Procedure
- Add equimolar concentrations of each DNA sample to a PCR tube
- Add 1.5 uL of each Forward and Reverse Primer
- Add 27.5 uL of KOD Hot Start Master Mix
- Add deionized water until the total volume is 50 uL
- Place in Themocycler
Thermocycler Conditions
Number of Cycles | From 20 - 40 |
---|---|
Annealing Temperature | Set temperature to the lowest primer melt temperature |
Extension Time | If target size is: < 500 bp run 10 sec/kb 500-1000 bp run 15 sec/kb 1000-3000 bp run 20 sec/kb < 3000 bp run 20 sec/kb |
Making a 1% Agarose Gel
Materials
- Agarose
- 1x TAE Buffer
- Ethidium Bromide
- 250 mL Flask
Procedure
- Add 0.6 g of agarose to 250 mL flask
- Add 60 mL of 1x TAE buffer and mix by swirling the flask
- Microwave mixture for 60 seconds
- Add 3 uL of Ethidium Bromide and mix gently
- Pour into gel tray with the desired comb size and wait 30 minutes for it to solidify
Agarose Gel Electrophoresis
Materials
- Agarose Gel
- 6x Loading Dye
- 2 log DNA ladder
- Gel Box
- 1x TAE Buffer
Procedure
- Add 6x loading dye to each sample
- Place agarose gel into gel box
- Fill gel box with 1x TAE buffer to fill line
- Load 2 log ladder and samples into wells
- Run gel at 135 V for 30-40 minutes