<h3> Mini-Prep Protocol </h3>
 +
<h4> Harvest Cell : </h4>
 +
<p> • Pellet 1-5 mL of an overnight recombinant E. coli culture by centrifugation.
 +
o The optimal volume of culture to use depends upon the plasmid and culture density.
 +
o For best yields for E. coli grown in LB:
 +
 use 1-3 mL of culture for high copy plasmids
 +
 use 1-5 mL of culture for low copy plasmids
 +
o for best yields for E. coli grown in TB or 2X YT:
 +
 use only 1 mL of culture
 +
1. Resuspend Cells (verify that appropriate volume RNase A solution was added to the Resuspension Solution
 +
a. Completely resuspend the bacterial pellet with 200 µL of the Resuspension Solution.
 +
b. Vortex or pipette up and down to thoroughly resuspend the cells until homogenous
 +
2. Lyse Cells
 +
a. Lyse the resuspended cells by adding 200 µL of the Lysis Solution
 +
b. Mix the contents by gentle inversion (6-8 times) until the mixture becomes clear and viscous (Don’t vortex)
 +
c. Do not allow the lysis reaction to exceed 5 minutes
 +
3. Neutralize
 +
a. Precipitate the cell debris by adding 350 µL of the Neutralization/Binding Solution
 +
b. Gently invert the tube 4-6 times
 +
c. Pellet the cell debris by centrifuging at ≥ 12,000 x g or maximum speed for 10 minutes
 +
d. Cell debris, proteins, lipids, SDS, and chromosomal DNA should fall out as a cloudy, viscous precipitate.
 +
e. If the supernatant contains a large amount of floating particulates after centrifugation, re-centrifuge the supernatant
 +
4. Prepare Column
 +
a. Insert a GenElute Miniprep Binding Column into a provided micro-centrifuge tube, if not already assembled
 +
b. Add 500 µL of the Column Preparation Solution to each miniprep column and centrifuge at ≥ 12,000 x g for 30 seconds to 1 minute
 +
c. Discard the flow-through liquid
 +
5. Load cleared lysate
 +
a. Transfer the cleared lysate from step 3 to the column prepared in step 4 and centrifuge at ≥ 12,000 x g for 30 seconds to 1 minute.
 +
b. Discard the flow-through liquid
 +
6. Wash Column (verify that ethanol has been added to the bottle of Wash Solution 2)
 +
a. Add 750 µL of the diluted Wash Solution to the column
 +
b. Centrifuge at ≥ 12,000 x g for 30 seconds to 1 minute
 +
c. Discard the flow-through liquid and centrifuge again at maximum speed for 1-2 minutes without any additional Wash Solution to remove excess ethanol
 +
7. Elute DNA
 +
a. Transfer the column to a fresh collection tube. Add 100 µL of Elution Solution or molecular biology reagent water to the column
 +
b. For DNA sequencing and other enzymatic application, use water or 5 Mm Tris-HCL, Ph 8.0, as an eluant
 +
c. Centrifuge at ≥ 12,000 x g for 1 minute
 +
d. Use immediately or store at -20˚C
 +