Introduction

It is significant for synthetic biology to develop a reliable and repeatable measurement, the same to all the other engineering disciplines. We HUST-China have volunteered to test some RBS devices (BCDs) that are intended to make gene expression more precise and reliable by measure the expression level of GFP, in order to help the iGEM community collect data about how reliable will these devices turn out to be in labs around the world.

Provenance and Release

①Individuals responsible for conducting InterLab study

Individuals Interlab Part
Kangyuan Yu, Haibo Huang, Ziyang Xiao, Shaofeng Liao created the devices
Efan Wang, Long Cheng, HuiPing Shi conducted the measurements
Efan Wang processed the data

②Corresponding email

Individuals Emails
Efan Wang erfan@hust.edu.cn
Kangyuan Yu u201612160@hust.edu.cn
Haibo Huang u201612177@hust.edu.cn
Ziyang Xiao u201612166@hust.edu.cn
Shaofeng Liao u201612159@hust.edu.cn
HuiPing Shi u201513154@hust.edu.cn
Long Cheng u201512127@hust.edu.cn

Chassis and Safety

What chassis did you use?

Escherichia coli DH5α

What Biosafety Level is your chassis?

BSL1

What PPE did you utilize during your experiments?

Tianming gloves

Songxinjiujiu labcoats

Instrument

What instrument did you use during your measurements?

plate reader

Please provide the brand and model of your instrument.

Flexstation 3

Calibration Protocol

A1. Protocol for Optical Density (OD600) Standard Measurement

Did you use pathlength correction during measurement?

Yes

Number of flashes per well

6

Orbital averaging (mm)

600

What temperature setting did you use during the measurement?

22℃

What type of 96-well plate did you use?

Black plate (preferred)

Did your plate have flat-bottomed or round-bottomed wells?

Flat

A2. Measurement Steps

B1. Protocol for FIuorescein Fluoresence standard curve

Did you use pathlength correction during measurement?

Yes

Number of flashes per well

6

What gain setting did you use?

Automatic

If you used a filter, what light wavelengths did it pass?

530nm

Emission wavelength

530nm

Excitation wavelength

485nm

Fluorescence reading

Bottom optic

What type of 96-well plate did you use?

Black plate (preferred)

Did your plate have flat-bottomed or round-bottomed wells?

Flat

What temperature setting did you use during the measurement?

22℃

B2. Measurement Steps

Part 1: Prepare the Fluorescein stock solution
Measurement work flow:

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1
Part 2: Prepare the serial dilutions of Fluorescein
  • ①Add 100 μl of 1xPBS into wells A2, B2, C2, D2....A12, B12, C12, D12.
  • ②Add 200 μl of 1x Fluorescein stock solution into A1, B1, C1, D1.
  • ③ Transfer 100 μl of Fluorescein stock solution from A1 into A2.
  • ④ Mix A2 by pipetting up and down 3x and transfer 100 μl into A3.
  • ⑤ Mix A3 by pipetting up and down 3x and transfer 100 μl into A4.
  • ⑥ Mix A4 by pipetting up and down 3x and transfer 100 μl into A5.
  • ⑦ Mix A5 by pipetting up and down 3x and transfer 100 μl into A6.
  • ⑧ Mix A6 by pipetting up and down 3x and transfer 100 μl into A7.
  • ⑨ Mix A7 by pipetting up and down 3x and transfer 100 μl into A8.
  • ⑩ Mix A8 by pipetting up and down 3x and transfer 100 μl into A9.
  • ⑪ Mix A9 by pipetting up and down 3x and transfer 100 μl into A10.
  • ⑫ Mix A10 by pipetting up and down 3x and transfer 100 μl into A11.
  • ⑬ Mix A11 by pipetting up and down 3x and transfer 100 μl into liquid waste.
  • ⑭ Take care not to continue serial dilution into column 12.
  • ⑮ Repeat dilution series for rows B, C, D.
  • ⑯ Measure fluorescence of all samples in all standard measurement modes in instrument.

Cell Culture Setup and Measurement

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1
Transformation:
  • control
  • Negative control
  • Test Device 1: J23101+I13504
  • Test Device 2: J23106+I13504
  • Test Device 3: J23117+I13504
  • Test Device 4: J23101.BCD2.E0040.B0015
  • Test Device 5: J23106.BCD2.E0040.B0015
  • Test Device 6: J23117.BCD2.E0040.B0015
Cell growth:
Cell growth, sampling, and assay
The initial OD600 measurement of our overnight cultures.
demo1
What type of media did you use for this step?

Luria Bertani

What type of vessel or container did you use to grow your cells?

50 ml Falcon tube

What temperature setting did you use during the measurement?

22℃

What type of 96-well plates did you use?

Black plates with transparent/clear bottom (preferred)

Flat

Measurement
  • Measure OD and fluorescence of all samples
Suggested Plate Layout for 96-well Plate

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

Interlab Resultn

OD600 Reference Point
demo1
Fluorescence standard curve

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

NOTE: 50uM Sample exceeds the range of measurements

OD600 Reference Point
demo1 demo1

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

Final scaling level determined from medium-high points likely to be less impacted by saturation or pipetting error.

If needed, you can shift which points are used, but it is likely better to correct instrument settings and protocol.

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1

Click on the picture and you can see a clearer picture.Then click on the return key of the browser and you can return.



demo1