<p>For the foundational advance of this experiment in the future, it would be advisable to expand the concentrations used for inductions. Currently, the concentrations used include 1E-14M, 1E-13M, 1E-12M, 1E-11M, 1E-10M, 1E-9M, 1E-8M, 1E-7M, 1E-6M, 1E-5M, and 1E-4M. From the experiments, it is seen that the most GFP expression occurs in higher concentrations from 1E-8M to 1E-4M. If the range is narrowed between the values to include 1E-4.5M, 1E-5.5M, 1E-6.5M, and 1E-7.5M, a better idea of how GFP is expressed can be analyzed. Also if more synthetic AHLs are able to be tested with these receivers, the characterization can be expanded and these receivers can be further analyzed on how they work in multiple systems.  
 
<p>For the foundational advance of this experiment in the future, it would be advisable to expand the concentrations used for inductions. Currently, the concentrations used include 1E-14M, 1E-13M, 1E-12M, 1E-11M, 1E-10M, 1E-9M, 1E-8M, 1E-7M, 1E-6M, 1E-5M, and 1E-4M. From the experiments, it is seen that the most GFP expression occurs in higher concentrations from 1E-8M to 1E-4M. If the range is narrowed between the values to include 1E-4.5M, 1E-5.5M, 1E-6.5M, and 1E-7.5M, a better idea of how GFP is expressed can be analyzed. Also if more synthetic AHLs are able to be tested with these receivers, the characterization can be expanded and these receivers can be further analyzed on how they work in multiple systems.  
  
<h2>Considerations for experimental replication
+
<h2>Considerations for experimental replication</h2>
<p>When replicating these inductions, it is important to note that these AHLs are dissolved in ethyl acetate and serial dilutions were performed to get the desired concentrations. These dilutions were done the day of induction, and kept at -20 degrees Celsius for optimum results and lowest chance of degradation before testing. Also when plating, the final concentration of each AHL in the wells were the concentrations listed, with 1% ethyl acetate. Freshly transformed bacteria cells and grown cultures also gave optimum results for induction.  
+
<p>When replicating these inductions, it is important to note that these AHLs are dissolved in ethyl acetate and serial dilutions were performed to get the desired concentrations. These dilutions were done the day of induction, and kept at -20 degrees Celsius for optimum results and lowest chance of degradation before testing. Also when plating, the final concentration of each AHL in the wells were the concentrations listed, with 1% ethyl acetate. Freshly transformed bacteria cells and grown cultures also gave optimum results for induction.<p>
  
  

Revision as of 03:59, 1 November 2017