Difference between revisions of "Team:NTHU Taiwan/Results"

Line 434: Line 434:
 
<font size=4>
 
<font size=4>
 
<p>
 
<p>
To make sure the plasmid is cloned into E.coli BL-21 strain, we extracted the plasmid from transformed E.coli.(figure 1) We validated the gene by PCR with specific primers and then we examined the result with Agarose gel electrophoresis. A successful cloning was verified from the results of a PCR performed with designed specific primers according to the theoretically expected length of horseradish peroxidase(927bp).
+
To make sure the plasmid is cloned into <I>E. coli</I> BL-21 strain, we extracted the plasmid from transformed <I>E. coli</I>.(figure 1) We validated the gene by PCR with specific primers and then we examined the result with Agarose gel electrophoresis. A successful cloning was verified from the results of a PCR performed with designed specific primers according to the theoretically expected length of horseradish peroxidase(927bp).
 
</p>
 
</p>
 
</font>
 
</font>
Line 475: Line 475:
 
<font size=4>
 
<font size=4>
 
<p>
 
<p>
To obtain functional horseradish peroxidase we need to purify the protein from E.coli, but this kind of protein does not have any function and it is called apoprotein. After the first time purification, we refolded the protein to construct the correct structure and then we activated the apo-HRP with hemin to produce the functional HRP. We examined the existence of this protein by SDS-PAGE after purification. (figure 3)
+
To obtain functional horseradish peroxidase we need to purify the protein from <I>E. coli</I>, but this kind of protein does not have any function and it is called apoprotein. After the first time purification, we refolded the protein to construct the correct structure and then we activated the apo-HRP with hemin to produce the functional HRP. We examined the existence of this protein by SDS-PAGE after purification. (figure 3)
 
</p>
 
</p>
 
</font>
 
</font>
Line 632: Line 632:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 10. E.coli with gene of monobody
+
Figure 10. <I>E. coli</I> with gene of monobody
 
</font>
 
</font>
 
</center>
 
</center>
Line 645: Line 645:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 11. E.coli with gene of ER-alpha
+
Figure 11. <I>E. coli</I> with gene of ER-alpha
 
</font>
 
</font>
 
</center>
 
</center>
Line 679: Line 679:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
We compared the difference between E.coli expressed RFP and RFP-INP(figure 13). After the lysis of culture expressing RFP-INP, most of RFP was on the fragments of the membrane. Due to the larger structure of plasma membrane, it is easily spin down. If RFP-INP is on the E.coli plasma membrane when we centrifuged the cell lysate, RFP-INP is spun down with the plasma membrane, and we see a red pellet.
+
We compared the difference between <I>E. coli</I> expressed RFP and RFP-INP(figure 13). After the lysis of culture expressing RFP-INP, most of RFP was on the fragments of the membrane. Due to the larger structure of plasma membrane, it is easily spin down. If RFP-INP is on the <I>E. coli</I> plasma membrane when we centrifuged the cell lysate, RFP-INP is spun down with the plasma membrane, and we see a red pellet.
 
</p>
 
</p>
 
</font>
 
</font>
Line 686: Line 686:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
On contract, after cell lysis of RFP expression E.coli, most of RFP suspended in the solution. Since the centrifugation force, we set in this experiment is not enough to spin down particles as small as RFP. We see RFP suspended in the supernatant even after centrifugation.
+
On contract, after cell lysis of RFP expression <I>E. coli</I>, most of RFP suspended in the solution. Since the centrifugation force, we set in this experiment is not enough to spin down particles as small as RFP. We see RFP suspended in the supernatant even after centrifugation.
 
</p>
 
</p>
 
</font>
 
</font>
Line 693: Line 693:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
This experiment showed that INP can bring RFP to the membrane of E.coli, and this result proved the function of INP.  
+
This experiment showed that INP can bring RFP to the membrane of <I>E. coli</I>, and this result proved the function of INP.  
 
</p>
 
</p>
 
</font>
 
</font>
Line 704: Line 704:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 13. 1 : Fragments of E.coli with gene of RFP-INP ; 2:  Fragments of E.coli with gene of RFP
+
Figure 13. 1 : Fragments of <I>E. coli</I> with gene of RFP-INP ; 2:  Fragments of <I>E. coli</I> with gene of RFP
 
</font>
 
</font>
 
</center>
 
</center>
Line 720: Line 720:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
To prove that our detection system can distinguish the sample has EDCs or not, we used IR spectrum to measure specific bonds on E.coli and verify the detection function.(Table 1)
+
To prove that our detection system can distinguish the sample has EDCs or not, we used IR spectrum to measure specific bonds on <I>E. coli</I> and verify the detection function.(Table 1)
 
</p>
 
</p>
 
</font>
 
</font>
Line 731: Line 731:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Table 1. The IR signals for E.coli
+
Table 1. The IR signals for <I>E. coli</I>
 
</font>
 
</font>
 
</center>
 
</center>
Line 739: Line 739:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
In the beginning, we try to use live cells for the detection system. However, we found that all the samples have the information of E.coli. Showing that there is no difference between the sample with 5mM EDCs and the sample with no EDCs. (Figure 14)
+
In the beginning, we try to use live cells for the detection system. However, we found that all the samples have the information of <I>E. coli</I>. Showing that there is no difference between the sample with 5mM EDCs and the sample with no EDCs. (Figure 14)
 
</p>
 
</p>
 
</font>
 
</font>
Line 750: Line 750:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 14 The IR spectrum of samples in different conditions (live E.coli)
+
Figure 14 The IR spectrum of samples in different conditions (live <I>E. coli</I>)
 
</font>
 
</font>
 
</center>
 
</center>
Line 759: Line 759:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
To decrease the activity of E.coli, we tried to freeze E.coli in -80℃ for 24 hours and use it after thawing on ice immediately. We found that there is a significant difference between the sample with 5mM EDCs and EDCs-free and the intensity of IR signals also decrease due to the reduction of mobility of E.coli.(Figure 15) This result can prove that our detection system can detect EDCs in the water.
+
To decrease the activity of <I>E. coli</I>, we tried to freeze <I>E. coli</I> in -80℃ for 24 hours and use it after thawing on ice immediately. We found that there is a significant difference between the sample with 5mM EDCs and EDCs-free and the intensity of IR signals also decrease due to the reduction of mobility of <I>E. coli</I>.(Figure 15) This result can prove that our detection system can detect EDCs in the water.
 
</p>
 
</p>
 
</font>
 
</font>
Line 770: Line 770:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 15. The IR spectrum of samples in different conditions (freezed E.coli)
+
Figure 15. The IR spectrum of samples in different conditions (freezed <I>E. coli</I>)
 
</font>
 
</font>
 
</center>
 
</center>
Line 787: Line 787:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
To prove our detection system can measure the concentration of EDCs, we use crystal violet to stain E.coli on the surface of gold and then observe the density of stained E.coli under microscope. Due to the surface tension force of water, there are lots of E.coli remained around the drop edge of sample, and we only observed the area in the middle of the sample to reduce the error. (Figure 16)
+
To prove our detection system can measure the concentration of EDCs, we use crystal violet to stain <I>E. coli</I> on the surface of gold and then observe the density of stained <I>E. coli</I> under microscope. Due to the surface tension force of water, there are lots of <I>E. coli</I> remained around the drop edge of sample, and we only observed the area in the middle of the sample to reduce the error. (Figure 16)
 
</p>
 
</p>
 
</font>
 
</font>
Line 806: Line 806:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
We observed the density of E.coli when the samples contained different concentration of BPA and NP from 5mM to 5nM (Figure 17 and 18). This result indicates that when the concentration of EDCs decreases, the density of E.coli will decrease as well.
+
We observed the density of <I>E. coli</I> when the samples contained different concentration of BPA and NP from 5mM to 5nM (Figure 17 and 18). This result indicates that when the concentration of EDCs decreases, the density of <I>E. coli</I> will decrease as well.
 
</p>
 
</p>
 
</font>
 
</font>
Line 837: Line 837:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
For the practical propose, we added trehalose (0.1M) to prevent ER-alpha from denaturing and increase the time of conservation. We also observed the density of E.coli with samples containing the different concentration of BPA and NP from 5mM to 5nM.(Figure 19 and 20) From the result of observation, we can find the similar tendency as the sample without trehalose.
+
For the practical propose, we added trehalose (0.1M) to prevent ER-alpha from denaturing and increase the time of conservation. We also observed the density of <I>E. coli</I> with samples containing the different concentration of BPA and NP from 5mM to 5nM.(Figure 19 and 20) From the result of observation, we can find the similar tendency as the sample without trehalose.
 
</p>
 
</p>
 
</font>
 
</font>
Line 869: Line 869:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
To clarify the relationship between the concentration of EDCs and the density of E.coli, we use image J to count the amount of E.coli on the surface. (Figure 21-24) From the results of imageJ, we can get the similar tendency as the result from the pictures of the microscope. However, the density of E.coli decreases in the presence of 0.1 M trehalose, and this result suggested that although trehalose can improve the time to store lyophilized E.coli, it can decrease the precision of our detection system.
+
To clarify the relationship between the concentration of EDCs and the density of <I>E. coli</I>, we use image J to count the amount of <I>E. coli</I> on the surface. (Figure 21-24) From the results of imageJ, we can get the similar tendency as the result from the pictures of the microscope. However, the density of <I>E. coli</I> decreases in the presence of 0.1 M trehalose, and this result suggested that although trehalose can improve the time to store lyophilized <I>E. coli</I>, it can decrease the precision of our detection system.
 
</p>
 
</p>
 
</font>
 
</font>
Line 923: Line 923:
  
 
<p>
 
<p>
To ensure the function of ER-alpha on the surface of E.coli, we compared the difference between the BL-21 E.coli and ER-alpha expressed E.coli in the different concentration of BPA and NP. (figure 25 and 26)From the results, we found that BL-21 can’t affect the outcomes of the detection system.
+
To ensure the function of ER-alpha on the surface of <I>E. coli</I>, we compared the difference between the BL-21 <I>E. coli</I> and ER-alpha expressed <I>E. coli</I> in the different concentration of BPA and NP. (figure 25 and 26)From the results, we found that BL-21 can’t affect the outcomes of the detection system.
 
</p>
 
</p>
  
Line 961: Line 961:
 
<font size="4">
 
<font size="4">
 
<p>
 
<p>
To further understand the limitation of the concentration that our system can achieve, we observed the density of E.coli in four different conditions of background. We find that when there are no EDCs in the sample, the density of E.coli is close to the concentration of EDCs below 5µM. Showing that our detection system can’t measure the concentration of EDCs less than 5µM.(Figure 25 and Table 2)
+
To further understand the limitation of the concentration that our system can achieve, we observed the density of <I>E. coli</I> in four different conditions of background. We find that when there are no EDCs in the sample, the density of <I>E. coli</I> is close to the concentration of EDCs below 5µM. Showing that our detection system can’t measure the concentration of EDCs less than 5µM.(Figure 25 and Table 2)
 
</p>
 
</p>
 
</font>
 
</font>
Line 984: Line 984:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Table 2. The amounts of E.coli in the 4 different backgrounds
+
Table 2. The amounts of <I>E. coli</I> in the 4 different backgrounds
 
</font>
 
</font>
 
</center>
 
</center>
Line 1,008: Line 1,008:
 
<center>
 
<center>
 
<font size=2>
 
<font size=2>
Figure 26. Expression of GFP in the E.coli for detection.
+
Figure 26. Expression of GFP in the <I>E. coli</I> for detection.
 
</font>
 
</font>
 
</center>
 
</center>

Revision as of 01:18, 31 October 2017

Results


PART I Degradation


Cloning of Horseradish Peroxidase


To make sure the plasmid is cloned into E. coli BL-21 strain, we extracted the plasmid from transformed E. coli.(figure 1) We validated the gene by PCR with specific primers and then we examined the result with Agarose gel electrophoresis. A successful cloning was verified from the results of a PCR performed with designed specific primers according to the theoretically expected length of horseradish peroxidase(927bp).

Figure 1.

Figure 2. Primers for VR backbone:1,3,5 ;primers for monobody:2,4,6


Expression and purification of apo-HRP and refolded-HRP


To obtain functional horseradish peroxidase we need to purify the protein from E. coli, but this kind of protein does not have any function and it is called apoprotein. After the first time purification, we refolded the protein to construct the correct structure and then we activated the apo-HRP with hemin to produce the functional HRP. We examined the existence of this protein by SDS-PAGE after purification. (figure 3)

Figure 3. SDS-PAGE for purification of HRP


Functional test of Horseradish Peroxidase


To prove the degradation ability of HRP, we mixed 25 µg of HRP with 1 mM H2O2 and BPA or NP in the 1 mL water. The environment of degradation is suitable for HRP to degrade the phenolic compounds(40℃ and pH=6-7). After degradation for 24 hours, we denatured HRP by briefly heating up to 80℃ and use LC-PDA (Liquid Chromatography - Photodiode Array detector) to analysis the result of degradation.(figure 4 and 5)

Figure 4. The result of LC-PDA (BPA sample)


Figure 5. The result of LC-PDA (NP sample)


From the result of LC-PDA, we found that there are two extra peaks showing after degradation and these extra peaks represent the by-products from degradation. Unfortunately, we can’t know how much EDCs is degraded by HRP because:


(1) The peak of the by-products overlap the peak of EDCs and we can’t get the information of remained EDCs. (There is a by-product have a broad peak from 2.2 min to 3.5min and its intensity also much higher than the peak of EDCs)


(2) The quality of the column from LC isn’t good enough to separate the by-products from EDCs due to their similar molecular properties. (This LC can’t distinguish between BPA and NP so we estimated that it can’t distinguish the degraded by-product from BPA or NP as well.)


Moreover, we use the mass spectrum to prove HRP can degrade BPA and NP by the signals of the large molecular weight of by-products.(figure 6-9) We found that there are lots of additional peaks show up after degraded by HRP, and this result can prove our HRP can degrade BPA and NP.

Figure 6 the mass spectrum of BPA

Figure 7 the mass spectrum of BPA after degradation

Figure 8 the mass spectrum of NP

Figure 9 the mass spectrum of NP after degradation


PART II Detection


Cloning of ER-alpha and monobody


We cloned the sequence of ER-alpha and Monobody into the vector, and then we transformed the plasmid into BL-21 competent cells, respectively.(Figure 10 and 11) After transformation, we extracted both plasmids from the cells and the vector was validated by gel electrophoresis.

Figure 10. E. coli with gene of monobody


Figure 11. E. coli with gene of ER-alpha


A successful cloning was verified from the results of a PCR performed with specifically designed primers according to the theoretically expected length of ER-alpha (2199bp) and Monobody (797bp).(Figure 12)

Figure 12 1 : RFP ( mRFP F-primer and mRFP R-primer ); 2 : IPTG (promoter) + INP + RFP2 (ER F-primer and ER R-primer ); 3 : IPTG (promoter) + INP + RFP 1 (ER F-primer and ER R-primer ) ; 4 : IPTG (promoter) + ER with red spot (ER F-primer and ER R-primer ); 5 : IPTG (promoter) + ER2 (ER F-primer and ER R-primer ); 6 : IPTG (promoter) + ER1 (ER F-primer and ER R-primer ); 7 : IPTG (promoter) + Monobody with red spot (Monobody F-primer and Monobody R-primer ); 8 : IPTG (promoter) + Monobody 2 (Monobody F-primer and Monobody R-primer ) ; 9 : IPTG (promoter) + Monobody 1 (Monobody F-primer and Monobody R-primer ); 10 : RFP ( VR primer and VF2 primer ); 11 : IPTG (promoter) + INP + RFP 2 ( VR primer and VF2 primer ); 12 : IPTG (promoter) + INP + RFP 1 ( VR primer and VF2 primer ); 13 : IPTG (promoter) + ER with red spot ( VR primer and VF2 primer ); 14 : IPTG (promoter) + ER2 ( VR primer and VF2 primer ); 15 : IPTG (promoter) + ER1 ( VR primer and VF2 primer ); 16 : IPTG (promoter) + Monobody with red spot ( VR primer and VF2 primer ); 17 : IPTG (promoter) + Monobody 2 ( VR primer and VF2 primer ); 18 : IPTG (promoter) + Monobody 1 ( VR primer and VF2 primer )


Function of ice nucleation protein (INP)


We compared the difference between E. coli expressed RFP and RFP-INP(figure 13). After the lysis of culture expressing RFP-INP, most of RFP was on the fragments of the membrane. Due to the larger structure of plasma membrane, it is easily spin down. If RFP-INP is on the E. coli plasma membrane when we centrifuged the cell lysate, RFP-INP is spun down with the plasma membrane, and we see a red pellet.


On contract, after cell lysis of RFP expression E. coli, most of RFP suspended in the solution. Since the centrifugation force, we set in this experiment is not enough to spin down particles as small as RFP. We see RFP suspended in the supernatant even after centrifugation.


This experiment showed that INP can bring RFP to the membrane of E. coli, and this result proved the function of INP.

Figure 13. 1 : Fragments of E. coli with gene of RFP-INP ; 2: Fragments of E. coli with gene of RFP


Characterization of detection system


To prove that our detection system can distinguish the sample has EDCs or not, we used IR spectrum to measure specific bonds on E. coli and verify the detection function.(Table 1)

Table 1. The IR signals for E. coli


In the beginning, we try to use live cells for the detection system. However, we found that all the samples have the information of E. coli. Showing that there is no difference between the sample with 5mM EDCs and the sample with no EDCs. (Figure 14)

Figure 14 The IR spectrum of samples in different conditions (live E. coli)


To decrease the activity of E. coli, we tried to freeze E. coli in -80℃ for 24 hours and use it after thawing on ice immediately. We found that there is a significant difference between the sample with 5mM EDCs and EDCs-free and the intensity of IR signals also decrease due to the reduction of mobility of E. coli.(Figure 15) This result can prove that our detection system can detect EDCs in the water.

Figure 15. The IR spectrum of samples in different conditions (freezed E. coli)


Proof of concept: quantifying a number of EDCs in the water


To prove our detection system can measure the concentration of EDCs, we use crystal violet to stain E. coli on the surface of gold and then observe the density of stained E. coli under microscope. Due to the surface tension force of water, there are lots of E. coli remained around the drop edge of sample, and we only observed the area in the middle of the sample to reduce the error. (Figure 16)

Figure 16 Tthe sample under 50X microscope


We observed the density of E. coli when the samples contained different concentration of BPA and NP from 5mM to 5nM (Figure 17 and 18). This result indicates that when the concentration of EDCs decreases, the density of E. coli will decrease as well.

Figure 17 The samples with different concentration of BPA under 500X microscope

Figure 18 The samples with different concentration of NP under 500X microscope


For the practical propose, we added trehalose (0.1M) to prevent ER-alpha from denaturing and increase the time of conservation. We also observed the density of E. coli with samples containing the different concentration of BPA and NP from 5mM to 5nM.(Figure 19 and 20) From the result of observation, we can find the similar tendency as the sample without trehalose.

Figure 19 The samples with different concentration of BPA in 0.1M trehalose under 500X microscope

Figure 20 the samples with different concentration of NP in 0.1M trehalose under 500X microscope


To clarify the relationship between the concentration of EDCs and the density of E. coli, we use image J to count the amount of E. coli on the surface. (Figure 21-24) From the results of imageJ, we can get the similar tendency as the result from the pictures of the microscope. However, the density of E. coli decreases in the presence of 0.1 M trehalose, and this result suggested that although trehalose can improve the time to store lyophilized E. coli, it can decrease the precision of our detection system.

Figure 21 Samples of BPA

Figure 22 Samples of NP

Figure 23 Samples of BPA in 0.1M trehalose

Figure 24 Samples of NP in 0.1M trehalose


To ensure the function of ER-alpha on the surface of E. coli, we compared the difference between the BL-21 E. coli and ER-alpha expressed E. coli in the different concentration of BPA and NP. (figure 25 and 26)From the results, we found that BL-21 can’t affect the outcomes of the detection system.

Figure 25. Samples of BPA

Figure 26. Sample of NP


The limitation of our detection system


To further understand the limitation of the concentration that our system can achieve, we observed the density of E. coli in four different conditions of background. We find that when there are no EDCs in the sample, the density of E. coli is close to the concentration of EDCs below 5µM. Showing that our detection system can’t measure the concentration of EDCs less than 5µM.(Figure 25 and Table 2)

Figure 25 The background of 4 different conditions

Table 2. The amounts of E. coli in the 4 different backgrounds


Part III Future Work

1. Since we failed to express GFP and ER-alpha at the same time, we will try to construct the gene containing GFP and ER-alpha and express them together for the purpose of detection. (Figure 26)

Figure 26. Expression of GFP in the E. coli for detection.


2. Since we don’t have time to construct the detection system to measure the change of fluorescence or surface plasmon resonance, we will construct the detection system to estimate the concentration of EDCs in the water precisely. (Figure 27)

Figure 27. Using the change of fluorescence to estimate the precise concentration of EDCs in the water