Difference between revisions of "Team:Uppsala/Safety"

Line 2: Line 2:
 
{{Uppsala/Navbar}}
 
{{Uppsala/Navbar}}
 
<html bgcolor="#92e0c0">
 
<html bgcolor="#92e0c0">
<head>
+
<head bgcolor="#92e0c0">
 
   <meta charset="utf-8">
 
   <meta charset="utf-8">
 
   <meta name="viewport" content="width=device-width, initial-scale=1">
 
   <meta name="viewport" content="width=device-width, initial-scale=1">
Line 11: Line 11:
 
<style type="text/css">
 
<style type="text/css">
 
p      {color:#ffffff;
 
p      {color:#ffffff;
         font-size: 3vh !important;
+
         font-size: 2vh !important;
 
         line-height:150%;
 
         line-height:150%;
 +
        text-align:justify;
 
}
 
}
  
Line 18: Line 19:
 
                 font-family:"Raleway";
 
                 font-family:"Raleway";
 
                 color:#ffffff;
 
                 color:#ffffff;
                 font-size: 5vh;
+
                 font-size: 5vh !important;
 
     }
 
     }
  
Line 39: Line 40:
 
<object data="https://static.igem.org/mediawiki/2017/4/48/Uppsala_safety_head.svg" style="width:100vw; height:auto"></object>
 
<object data="https://static.igem.org/mediawiki/2017/4/48/Uppsala_safety_head.svg" style="width:100vw; height:auto"></object>
 
</head>
 
</head>
<body>
+
<body bgcolor="#92e0c0">
 
<div class="container-fluid">
 
<div class="container-fluid">
 
<div class="row" style="height:auto;">
 
<div class="row" style="height:auto;">
Line 47: Line 48:
 
<div class="container-fluid magix collapse"  id="text1" style="width:100%;">
 
<div class="container-fluid magix collapse"  id="text1" style="width:100%;">
 
<h3><b>General lab safety and security</b></h3><br>
 
<h3><b>General lab safety and security</b></h3><br>
<div style="text-align: left;color:#ffffff;font-family:'Roboto Slab;font-size:3vh;"><p>Safety is very important when working in a laboratory. For this we had an organized tour of safety by a lab technician before lab work started to make sure everyone knew how to behave safely in the laboratory. The demonstration tour included how to handle waste, safety hoods, fire safety, emergency exits, biosafety and how to protect yourself while working in the lab, such as wearing lab coats and gloves/safety glasses when needed. All single use lab material such as pipette tips, plastic loops etc were disposed in special hazardous waste containers. To make sure medium as well as lab equipment was sterile we used autoclavation. Since the machine operates under high pressure and temperature we limited the risk of accidents happening by only letting certain people from the team operate the machine. The lab was a restricted area where only the team and certain university personnel had access to. All chemicals were stored in a locked room in alphabetical order and the lab was checked and locked at the end of each day to make sure everything was in order.<br><br><br><br><br><br><br><br></p> </div>
+
<p>Safety is very important when working in a laboratory. For this we had an organized tour of safety by a lab technician before lab work started to make sure everyone knew how to behave safely in the laboratory. The demonstration tour included how to handle waste, safety hoods, fire safety, emergency exits, biosafety and how to protect yourself while working in the lab, such as wearing lab coats and gloves/safety glasses when needed. All single use lab material such as pipette tips, plastic loops etc were disposed in special hazardous waste containers. To make sure medium as well as lab equipment was sterile we used autoclavation. Since the machine operates under high pressure and temperature we limited the risk of accidents happening by only letting certain people from the team operate the machine. The lab was a restricted area where only the team and certain university personnel had access to. All chemicals were stored in a locked room in alphabetical order and the lab was checked and locked at the end of each day to make sure everything was in order.<br><br><br><br><br><br><br><br></p> </div>
 
  </div>
 
  </div>
  

Revision as of 19:41, 1 November 2017

Hazardous chemicals

Acrylamide:
Acrylamide is used in SDS-PAGE. The substance is toxic which can cause skin and eye irritation and can cause after long exposure organ damage. To protect us when using the substance thick nitrile gloves, safety glasses and lab coats were used. When handling the substance the one working with it was always extra cautious and disposed anything that might have come in contact with the substance in a special hazardous waste container.

Antibiotics:
Antibiotic is classified as a drug according to swedish law and is currently increasing in resistance in the environment. When handling the substance gloves, lab coats and glasses were worn and material that was used in contact with the substance were sorted into contagious waste boxes. Small liquid cultures including antibiotics were treated with “Jodopax” to destroy the chemical.

Liquid nitrogen:
Liquid nitrogen was used to snap freeze when making our competent cells. When liquid nitrogen is very cold it has a boiling temperature of −196 °C which means it needs to be handled with care. That’s why a special thermos was used to make sure the gaseous nitrogen could escape to keep the pressure low. When liquid nitrogen was used it was handled with care and safety goggles, lab coat and insulating gloves were worn at all times.

Nickel Sepharose Fast Flow:
The substance contains nickel, which can cause allergic reactions when come in contact with. The nickel ions are also flammable. The substance was kept away from fire and heat at all times. The substance was handled with care and gloves were worn at all times. Contaminated liquid was disposed contagious waste boxes as nickel is dangerous for the environment.

PDMS:
PDMS or Polydimethylsiloxane is a silicon-based organic polymer. The product is non-toxic below 180 ℃. Higher temperatures may release hazardous gases. However it was never used at such high temperatures. The product can cause eye irritation so glasses, gloves and lab coats were worn at all times.

Chloroform:
Chloroform was used to clean PDMS as well as for cleaning where P1 phage was used. The substance evaporates at room temperature and is dangerous. That why all work with the substance was done in the fume hood with clearly marked bottles. Nitrile gloves, glasses and laboratory coat were worn.