MarkusHaak (Talk | contribs) |
|||
Line 120: | Line 120: | ||
</article><div class="figure small"> | </article><div class="figure small"> | ||
<img class="figure image" src="https://static.igem.org/mediawiki/2017/7/70/T--Bielefeld-CeBiTec--YKE_markus_bohrend_for_the_column.jpg"> | <img class="figure image" src="https://static.igem.org/mediawiki/2017/7/70/T--Bielefeld-CeBiTec--YKE_markus_bohrend_for_the_column.jpg"> | ||
− | <p class="figure subtitle"><b>Figure 9: Preparation of the non-3D-printed parts at the home of | + | <p class="figure subtitle"><b>Figure 9: Preparation of the non-3D-printed parts at the home of team member Markus.</b> |
</div> | </div> | ||
<article> | <article> |
Revision as of 14:11, 27 August 2017
Overview
Purification Column EluX
To verify the elution as easily as possible, we created a fusion protein containing GFP for a visible fluorescence signal and streptavidin to immobilize the protein in our column using biotin. The two protein parts are connected through a flexible glycine-glycine-serine-linker of eleven amino acids, in which the sixth amino acid is our 2-NPA. This ncAA will then induce the cleavage of our target protein (GFP) from the streptavidin compound in the purification process.
Development
Purification Column EluX
Figure 1: The six steps in the development process of the purification column
A) BSA-coated micro well plate, B) Hollow cylindrical column, C) Biotinylated microscope slides, D) First flow model, E) second flow model, F) future concept of a microfluidic like column.
BSA-coated micro well plate
Figure 2: Concept of a microwell plate coated with biotinylated BSA.
Cylindrical column
Figure 3: Concept of our cylindrical column
3D-Modell of a hollow column with an LED-rod in the middle and a carrier material coated with biotinylated BSA as first concept of a purification system using 2-NPA.
Biotinylated glass slide
Figure 4: Three microscope glass slides as basis for biotinylated surfaces for the purification column.
First flow model
Figure 5: EluX prototype one.
First flow model of a purification column with parallel biotinylated glass slides inside and UV-permeable acrylic glass plates in front and back to enable the radiation with light of 365 nm wave length.
Second flow model
Figure 6: EluX prototype two.
Second flow model of a purification column as basis for a workshop and a 3D-printed model to test, evaluate and improve the concept of light induced elution.
Future microfluidic / flow-bundle model
Figure 7: Future concept of EluX.
Concept of a microfluidic like (a) and a bundle (b) purification column designed with the support of Dr. Benjamin Müller and Prof. Dr. Dirk Lütkemeyer as future prediction of how the procedure of light induced elution could be used.
Construction
Purification column EluX
3D-Printed show model
Figure 8: 3D-printed parts of the purification column.
Figure 9: Preparation of the non-3D-printed parts at the home of team member Markus.
Figure 10: Inside and outside of the EluX prototype.
Figure 11: Comparison of the build and presented show model and the 3D-Model.