Difference between revisions of "Team:Kent/Experiments"

Line 760: Line 760:
 
<input type="radio" name="droptext" id="cb11" />
 
<input type="radio" name="droptext" id="cb11" />
 
<section class="hull">
 
<section class="hull">
<label class="hull-title" for="cb11">Production of Glycerol stock</label>
+
<label class="hull-title" for="cb11">Fluorescein Fluorescence Standard Curve</label>
 
<label class="hull-close" for="acc-close"></label>
 
<label class="hull-close" for="acc-close"></label>
<div class="hull-content">If you wish to store bacteria long term, you will need to create a Glycerol Stock after
+
<div class="hull-content">
inoculating an overnight liquid culture
+
A dilution series of Fluorescein in 4 replicates must be prepared where the
 +
fluorescence is measured in a 96 well plate in standard mode on a plate reader. A
 +
standard curve will be generated of fluorescence of fluorescein concentration. This
 +
will be used to correct cell based readings to an equivalent fluorescein
 +
concentration, which will then be converted into a GFP concentration
 
<br>
 
<br>
<ul><li>Once bacterial growth has been achieved, 500μL of the overnight liquid
+
Materials
culture needs to be added to 500μL of 50% glycerol in a 2mL tube where it
+
<ul><li>Fluorescein</li>
should be gently mixed</li>
+
<li>10mL 1xPBS (Phosphate Buffered Saline)</li>
<li>The glycerol stock should then be frozen at -80 o C<ul>
+
<li>96 well plate (black with flat, transparent/clear bottom)</li></ul>
<li> Successive freeze and thaw cycles will reduce the stocks shelf life</li></ul>
+
<br>
</li></ul></div>
+
Method:
 +
Serial dilutions need to be performed across columns 1-11
 +
Column 12 must contain PBS buffer only
 +
<br>
 +
The plate will initially be setup fluorescein stock in column 1 and equal volume of1xPBS in columns 2-12
 +
<ul><li> Add 100 µL of PBS into wells A2-A12, B2-B12, C2-C12 and D2-D12</li>
 +
<li>Add 200 µL of Fluorescein 1x stock solution into A1, B1, C1 and D1</li>
 +
 
 +
<li>Transfer 100 µL of Fluorescein stock solution from A1 into A2</li>
 +
<li>Mix A2 by pipetting up and down 3x and transfer 100 µL into A3
 +
Repeat the process for A3 into A4, A4 into A5, etc. until A11</li>
 +
<li>Mix A11 by pipetting up and down 3x and transfer 100 µL into liquid waste</li>
 +
<li>Repeat dilution series for rows B, C and D</li>
 +
<li>Measure fluorescence of all samples in all standard measurement modes in
 +
instrument</li>
 +
<li>Record the data</li></ul>
 +
<br>
 +
Measurement notes
 +
<ul><li>The plates can now be measured in the plate reader</li>
 +
<li>Standard GFP settings must be used (same as those used when measuring the
 +
cells):<ul>
 +
<li>Excitation 485nm
 +
<li>Emission 530/30
 +
<li>Turn off path length correction</li></ul></li>
 +
<li>Would be ideal to repeat measurements with different settings
 +
</ul><li>Generates series of standard curves to choose from</li></ul></li>
 +
<li>Use number of settings that affect sensitivity (gain and/or slit width)
 +
<ul><li>Also consider orbital averaging, top/bottom optics</li></ul></li>
 +
 
 +
</div>
 
</section>
 
</section>
 
<input type="radio" name="droptext" id="acc-close" />
 
<input type="radio" name="droptext" id="acc-close" />

Revision as of 19:24, 29 October 2017


Experiments & Protocols