Difference between revisions of "Team:Potsdam/Protocols"

Line 54: Line 54:
  
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. Restriction using biobrick assembly enzymes <br>
+
1. Restriction using biobrick assembly enzymes. <br>
  
2. This preparation step is needed to create sticky ends on the cassettes <br>
+
2. This preparation step is needed to create sticky ends on the cassettes. <br>
  
3. This step is only performed once <br>
+
3. This step is only performed once. <br>
  
4. Restriction with EcoRI and PstI (see restriction protocol) for all components </div>
+
4. Restriction with EcoRI and PstI (see restriction protocol) for all components. </div>
  
  
Line 104: Line 104:
 
<div style="text-align: justify; margin-left:20px">3. Final preparation steps </div>
 
<div style="text-align: justify; margin-left:20px">3. Final preparation steps </div>
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. Transformation of 9 different combinations into competent cells (see transformation protocol)<br>
+
1. Transformation of 9 different combinations into competent cells (see transformation protocol).<br>
2. Selection with corresponding antibiotics</div>
+
2. Selection with corresponding antibiotics.</div>
 
<br>
 
<br>
 
<div style="text-align: justify; margin-left:20px">4. Next day</div>
 
<div style="text-align: justify; margin-left:20px">4. Next day</div>
 
<div style="text-align: justify; margin-left:40px">  
 
<div style="text-align: justify; margin-left:40px">  
1. Colony pcr and gel run to check for sizes of cassettes <br>
+
1. Colony pcr and gel run to check for sizes of cassettes. <br>
  
2. Miniprep and check concentration via nanodrop <br>
+
2. Miniprep and check concentration via nanodrop. <br>
  
 
3. Many aliquots needed (small volume because thawing time) for future reactions!</div>
 
3. Many aliquots needed (small volume because thawing time) for future reactions!</div>
Line 120: Line 120:
 
<div style="text-indent:20px;">1. Good to know </div>
 
<div style="text-indent:20px;">1. Good to know </div>
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. The 3-A-assembly will be used to add more and more cassettes in a row <br>
+
1. The 3-A-assembly will be used to add more and more cassettes in a row. <br>
  
2. It is important to only combine cassettes with the same number (1, 2 and 3 have varying spacer length)<br>
+
2. It is important to only combine cassettes with the same number (1, 2 and 3 have varying spacer length).<br>
  
3. We will add cassettes and test frequently for viability to determine the maximum target-sequence length<br>
+
3. We will add cassettes and test frequently for viability to determine the maximum target-sequence length.<br>
  
4. We want to combine about five cassettes </div>
+
4. We want to combine about five cassettes. </div>
 
<br>
 
<br>
  
Line 133: Line 133:
  
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. In each assembly cycle, there will be two cassettes (same number/length) added to one linearized plasmid <br>
+
1. In each assembly cycle, there will be two cassettes (same number/length) added to one linearized plasmid. <br>
  
2. In the first step, we can either just use the prepared plasmid with cassettes already inserted or use an empty one, because the part in between will be cut out anyway <br>
+
2. In the first step, we can either just use the prepared plasmid with cassettes already inserted or use an empty one, because the part in between will be cut out anyway. <br>
  
3. The be able to select for plasmid with higher cassette content the resistances will cycle<br>
+
3. The be able to select for plasmid with higher cassette content the resistances will cycle.<br>
  
4. The resistance cycle (for plasmids) is K C A <br>
+
4. The resistance cycle (for plasmids) is K C A. <br>
  
5. For the inserts, the resistance signals from which plasmid they will be cut<br>
+
5. For the inserts, the resistance signals from which plasmid they will be cut.<br>
  
 
6. The plasmids resistance determines the selection antibiotics for that step!</div>
 
6. The plasmids resistance determines the selection antibiotics for that step!</div>
Line 198: Line 198:
  
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. Insert 1 is cut out of plasmid C1/Insert 2 is cut out of plasmid A1 and plamsid K1 is linearized <br>
+
1. Insert 1 is cut out of plasmid C1/Insert 2 is cut out of plasmid A1 and plamsid K1 is linearized .<br>
  
2. Insert 1 and 2 are ligated into plasmid K1 <br>
+
2. Insert 1 and 2 are ligated into plasmid K1. <br>
3. Insert 1 is cut out of plasmid A2/Insert 2 (here the fusion from Insert 1+2 from the first cycle) is cut out of K1 and plasmid C2 is linearized <br>
+
3. Insert 1 is cut out of plasmid A2/Insert 2 (here the fusion from Insert 1+2 from the first cycle) is cut out of K1 and plasmid C2 is linearized. <br>
4. Insert 1 and 2 are ligated into plasmid C2<br>
+
4. Insert 1 and 2 are ligated into plasmid C2.<br>
  
5. With insert 1 coming from K3 and insert 2 from C2 (fusion) the steps will repeated until maximum number of inserts is reached <br>
+
5. With insert 1 coming from K3 and insert 2 from C2 (fusion) the steps will repeated until maximum number of inserts is reached. <br>
  
  
6. The assembly needs to be done for all 3 cassettes simultaneously after each step
+
6. The assembly needs to be done for all 3 cassettes simultaneously after each step.
 
<br>
 
<br>
7. Transformation of ligation into competent cells (see transformation protocol)
+
7. Transformation of ligation into competent cells (see transformation protocol).
 
<br>
 
<br>
8. Selection with corresponding antibiotics </div>
+
8. Selection with corresponding antibiotics. </div>
 
<br>
 
<br>
 
<div style="text-indent:20px;">5. Next day</div>
 
<div style="text-indent:20px;">5. Next day</div>
  
 
<div style="text-align: justify; margin-left:40px">
 
<div style="text-align: justify; margin-left:40px">
1. Colony pcr and gel run to check for sizes of cassettes
+
1. Colony pcr and gel run to check for sizes of cassettes.
 
<br>
 
<br>
2. Miniprep and check concentration via nanodrop</div>
+
2. Miniprep and check concentration via nanodrop.</div>
 
<br> <br>
 
<br> <br>
 
<hr size="10" noshade></hr>
 
<hr size="10" noshade></hr>
  
<p style="font-size:15pt;"></sup><sup>[1]
+
<p style="font-size:15pt;"><sup>[1]</sup>
 
http://parts.igem.org/Help:Protocols/3A_Assembly</p>
 
http://parts.igem.org/Help:Protocols/3A_Assembly</p>
 
  </div></div></div>
 
  </div></div></div>

Revision as of 14:37, 31 October 2017

No Sidebar - Escape Velocity by HTML5 UP

Our research work

We are describing our research work. Below you can find the protocols we used.

Protocols