(Edit required for judging form evaluation.) |
(Content Added) |
||
Line 1: | Line 1: | ||
− | {{ | + | {{WarwickHeader}} |
<html> | <html> | ||
+ | <div class="container"> | ||
+ | <div class="hwrap"> | ||
+ | <h2>Interlab Study</h2> | ||
+ | <h3><i>How close can the numbers be when fluorescence is measured all around the world?</i></h3> | ||
+ | </div> | ||
+ | <br> | ||
+ | <div class="col-lg-12 col-centered text-justified"> | ||
+ | <p><strong>Goal:</strong> To establish a GFP measurement protocol based on engineering principles that anyone with a plate reader can use in their lab. Participants of the study were enlisted to produce common, comparable units of measuring GFP with different plate readers. We also tested some RBS devices (BCDs) which are intended to make gene expression more precise and reliable.</p> | ||
+ | <p>We were supplied with eight plasmids containing the composite parts needed for the study. We also received a Measurement Kit from iGEM HQ, which was used to generate the standard curve needed to measure our parts.</p> | ||
+ | <a href="https://static.igem.org/mediawiki/2017/d/d6/T--Warwick--2-InterlabProtocol.pdf"><p><strong>Protocol</p></a> | ||
+ | <p><strong>Results:</strong> Our results can be found here…</p> | ||
+ | </div> | ||
− | + | <div class="hwrap"><h4>TARGET DILUTION CALCULATION</h4></div> | |
− | <div class=" | + | <img src="https://static.igem.org/mediawiki/2017/f/fd/T--Warwick--2-TargetDilutionCalculation.png" class="img-responsive center-block"/> |
− | < | + | <div class="hwrap"><h4>OD600 REFERENCE POINT</h4></div> |
− | < | + | <img src="https://static.igem.org/mediawiki/2017/0/08/T--Warwick--2-OD600ReferencePoint.png" class="img-responsive center-block"/> |
− | < | + | <div class="hwrap"><h4>FLUORESCEIN STANDARD CURVE</h4></div> |
− | < | + | <img src="https://static.igem.org/mediawiki/2017/f/f7/T--Warwick--2-FluoresceinStandardCurve1.png" class="img-responsive center-block"/><br/> |
− | + | <img src="https://static.igem.org/mediawiki/2017/3/37/T--Warwick--2-FluoresceinStandardCurve2.png" class="img-responsive center-block"/> | |
− | + | <div class="hwrap"><h4>OD600 REFERENCE POINT</h4></div> | |
− | </ | + | <div class="row"> |
+ | <div class="col-xs-6"><img src="https://static.igem.org/mediawiki/2017/7/7b/T--Warwick--2-OD600Ref1.png" class="img-responsive center-block"/></div> | ||
+ | <div class="col-xs-6"><img src="https://static.igem.org/mediawiki/2017/2/27/T--Warwick--2-OD600Ref2.png" class="img-responsive center-block"/></div> | ||
+ | </div> | ||
</div> | </div> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</html> | </html> | ||
+ | {{WarwickFooter}} |
Latest revision as of 16:39, 1 November 2017
Interlab Study
How close can the numbers be when fluorescence is measured all around the world?
Goal: To establish a GFP measurement protocol based on engineering principles that anyone with a plate reader can use in their lab. Participants of the study were enlisted to produce common, comparable units of measuring GFP with different plate readers. We also tested some RBS devices (BCDs) which are intended to make gene expression more precise and reliable.
We were supplied with eight plasmids containing the composite parts needed for the study. We also received a Measurement Kit from iGEM HQ, which was used to generate the standard curve needed to measure our parts.
Protocol
Results: Our results can be found here…