Line 194: | Line 194: | ||
<div class="content" style="display: none;"> | <div class="content" style="display: none;"> | ||
<p style="text-align:justify"> | <p style="text-align:justify"> | ||
− | <h2><b>Methods</b></h2> | + | <h2><b>Methods - Patch Clamp</b></h2> |
− | + | ||
<ul> | <ul> | ||
<li>We used whole-cell patch clamp to measure the membrane voltage and ion currents across a HEK cell membrane. To measure whole-cell, we pushed a glass pipette against the membrane of a cell, to seal the membrane completely against the membrane. Afterwards, we caused a sudden negative pressure in the glass pipette, which destroys the membrane in the opening of the glass pipette. The solution within the pipette will subsequentially mix with the intracellular compartment of the cell, which allows us to measure with a pre-defined intracellular buffer.</li> | <li>We used whole-cell patch clamp to measure the membrane voltage and ion currents across a HEK cell membrane. To measure whole-cell, we pushed a glass pipette against the membrane of a cell, to seal the membrane completely against the membrane. Afterwards, we caused a sudden negative pressure in the glass pipette, which destroys the membrane in the opening of the glass pipette. The solution within the pipette will subsequentially mix with the intracellular compartment of the cell, which allows us to measure with a pre-defined intracellular buffer.</li> | ||
Line 217: | Line 217: | ||
<div class="content" style="display: none;"> | <div class="content" style="display: none;"> | ||
<p style="text-align:justify"> | <p style="text-align:justify"> | ||
− | <h2><b> | + | <h2><b>Preparation of imaging</b></h2> |
<h5><b>Fura-2, AM</b> (MW: 1001,9)</h5> | <h5><b>Fura-2, AM</b> (MW: 1001,9)</h5> | ||
<ul> | <ul> | ||
Line 224: | Line 224: | ||
<li>To load cells (1 well): add 2 μl of Fura-2 to 1 ml of medium (2μM work solution)</li> | <li>To load cells (1 well): add 2 μl of Fura-2 to 1 ml of medium (2μM work solution)</li> | ||
<li>Incubate cells for 30 minutes before measurement</li> | <li>Incubate cells for 30 minutes before measurement</li> | ||
− | </ul> </div> | + | </ul> |
+ | </div> | ||
<br> | <br> | ||
<div class="experiment"> | <div class="experiment"> | ||
Line 234: | Line 235: | ||
<div class="content" style="display: none;"> | <div class="content" style="display: none;"> | ||
<p style="text-align:justify"> | <p style="text-align:justify"> | ||
− | <h4> | + | <h4>Intracellular Buffers</h4> |
− | + | <h4>Extracellular Buffers</h4> | |
− | + | ||
− | + | ||
− | <h4>Buffers</h4> | + | |
</div> | </div> | ||
</div> | </div> |
Revision as of 13:47, 4 September 2017
Protocols
In the lab, we used different experimental procedures. There are protocols for the wet and bacterial lab, for the cell culture lab and for the electrophysiology lab.