LukasPlatz (Talk | contribs) |
|||
Line 11: | Line 11: | ||
<h1>Introduction</h1> | <h1>Introduction</h1> | ||
+ | |||
+ | As a contribution to this years iGEM Goes Green study | ||
{{Heidelberg/templateus/Imagebox|https://static.igem.org/mediawiki/2017/2/2b/T--Heidelberg--2017_igemgoesgreen-logo.png|||pos = left}} | {{Heidelberg/templateus/Imagebox|https://static.igem.org/mediawiki/2017/2/2b/T--Heidelberg--2017_igemgoesgreen-logo.png|||pos = left}} |
Revision as of 13:06, 26 October 2017
iGEM Goes green.
Optimisations of PACE to reduce medium consumption
Introduction
As a contribution to this years iGEM Goes Green studyMedium consumption model
PACE usually consumes an extraordinary amount of medium per experiment. This is due to the need for a continuous supply of host E. coli with a constant cell density. This can be achieved either by using a turbidostat or a chemostat. Here we provide a tool to both the community and ourselves to calculate medium consumption based on different tunable parameters of PACE. We also want to gain an understanding on how we can reduce the amount of medium needed for an experiment. Medium consumption is critical when it comes to the energy needed for an experiment because autoclaving needs a lot of energy. In a turbidostat the cell density is held constant by adjusting the medium influx to the cell density. That means the growht of the E. coli is not affected, instead for every new E. coli one E. coli is put to wate. In a Chemostat the cell density is controlled by adjusting the influx of an essential nutrient to the cell density, which limits the growth of the culture. This may cause the E. coli to be less efficient in producing producing the proteins needed for PACE and replicating the phage genome. Additionally there is a constant eflux from the chemostat to the lagoons, that compensates the growth of the E. coli. Currently we are using a turbidostat, because probably PACE works better when the E. coli are allowd to grow at their maximum speed under the given conditions. So their ability to produce phage as fast as possible is not impaired. Here we can make statements on how much energy we save with a specific setup relative to another one, but we do not estimate the absolute amount of energy that is used.Configure the plot:
"Resolution" controls how many datapoints are calculated in each dimension, therefore complexity of both memory and computation increased with the square of resolution. Increase for a smoother heatmap and decrease for a faster result. "Flow trough Turbidostat" \(\Phi_{T}\), the amount of medium that is pumped trough the turbidostat during one hour. Depends on turbidostat volume \(V_{T}\), lagoon volume \(V_{L}\) and quantity \(N_{L}\), flow trough lagoon \(\Phi_{L}\). A larger total lagoon volume with a higher flow requires higher flow through the turbidostat. For turbidostat the flow rate \(\Phi_{T}\) can be calculated using the volume of the turbidostat \(V_{T}\) and the generation time of the E. coli \(t_{E}\) and has not to be set. "Maximum Duration" \(t_{max}\) controls the upper border of the y-axis. "Generation Time E. coli" \(t_{E}\) sets the time in which the E. coli population doubles itself when in exponential phase. Only affects values for turbidostats, because chemostats control the generation time themselves. "Volume of Turbidostat" \(V_{T}\) actually the volume of the culture in the turbidostat. Only affects Turbidostats. Calculation of the flow trough a turbidostat: $$ \frac{\partial V_{M} }{\partial t} = \Phi_{T} = \frac{log(2)}{t_{E} } \cdot V_{T} $$Read the plot:
When working with a turbidostat the upper x axis is relevant, when working with a chemostat the lower is. Put the mouse pointer on the heatmap to show the exact values for that point. You can zoom in by drawing the rectangle that should be shown with pressed left mouse button. You can always save the current plot by clicking on the camera icon.Caution
Submitting one of the forms recalculates all values and the heatmap based on the values in all the forms.
Configure the plot
Table 2: Additional Variables and Parameters used in the numeric solution of the model List of all additional paramters and variables used in the numeric solution of this model. When possible values are given.
Symbol | Value and Unit | Explanation |
---|---|---|
\(V_{T}\) | [ml] | Volume of Turbidostat |
\(V_{M}\) | [ml] | Volume of Medium consumed |
\(t_{E} \) | [min] | E. coli generation time |
\(\Phi_{T}\) | ml/h |
Flow rate trough turbidostat |
\(t_{max}\) | [min] | Duration of the experiment |
Your experiment
You can annotate a point in the heatmap by providing it's coordinates \(t_{max}\) and \(\Phi_{T}\) or \(V_{T}\) and and it's name. If you have a turbidostat, the value for the flow rate \(\Phi_{T}\) is ignored, if you have a chemostat, the volume \(V_{T}\) is ignored. For the calculation of the flow through the turbidostat, the value for generation time from the form above is used. Enter your specifications:
Annotate the plot
Minmal Turbidostat Volume
As larger turbidostats or chemostats with a larger flow need more medium for the same duration than smaller ones, working with the minimal required volume or flow is a way to save medium and thus energy. The minimal flow that is required can be calculated using $$ V_{T} = b \cdot V_{L} \cdot N_{L} \cdot \Phi_{L} $$ In case of fluctuations in the generation time of the E. coli it is crucial to have a buffer so that the turbidostat is not diluted, when the culture grows slower. We currently use a buffer of 50 %, so \(b\) is set to \(1.5\). For a turbidostat, the volume can be calculated from the flow using $$ V_{T} = \Phi_{T} \cdot \frac{t_{E} }{log(2)} $$ The calculation is based on wether turbidostatat or chemostat is picked above.Minimal Turbidostat Volume
Minimal Lagoon Volume
Obviously smaller lagoons require smaller turbidostats or chemostats with a lower flow and are therefore saving medium. However it there is a lower limit to lagoon size, if the phage population is too small, the sequence space that can be coverd is insufficient to find variants that are better than previous ones. Lagoon sizes used by other vary from 15 mlMinimal Lagoon Volume
References