<p>As a final characterisation of our biosensor, we carried out Dose Response assays in order to investigate the detection sensitivity. In this experiment, eleven different concentrations of the β-lactam antibiotics and bacitracin (control) have been tested together with the biosensor 2. This biosensor was chosen due to its reliable performance in liquid and on solid medium and because all necessary components are constitutively expressed without the addition of any further substances (as with biosensor 3).</p>
<p>As a final characterisation of our biosensor, we carried out Dose Response assays in order to investigate the detection sensitivity. In this experiment, eleven different concentrations of the β-lactam antibiotics and bacitracin (control) have been tested together with the biosensor 2. This biosensor was chosen due to its reliable performance in liquid and on solid medium and because all necessary components are constitutively expressed without the addition of any further substances (as with biosensor 3).</p>
<p>The obtained results (see Figure 5) indicate that biosensor 2 shows the highest dynamic range for cefoperazone and is capable to even sense very low concentrations of this compound. Biosensor 2 shows the weakest dose response towards cefalexin, which is in agreement with all previous experiments (see Figure 5). The antibiotics cefalexin, ampicillin and penicillin G lead to a decrease in luminescence signal for concentrations higher than 10<sup>-1</sup>, due to the growth inhibition at these concentrations (see Figure 5). Over all, a high dynamic range upon antibiotic exposure can be detected for all compounds starting at concentrations above 10<sup>-3</sup>.</p></figure>
<p>The obtained results (see Figure 5) indicate that biosensor 2 shows the highest dynamic range for cefoperazone and is capable to even sense very low concentrations of this compound. Biosensor 2 shows the weakest dose response towards cefalexin, which is in agreement with all previous experiments (see Figure 5). The antibiotics cefalexin, ampicillin and penicillin G lead to a decrease in luminescence signal for concentrations higher than 10<sup>-1</sup>, due to the growth inhibition at these concentrations (see Figure 5). Over all, a high dynamic range upon antibiotic exposure can be detected for all compounds starting at concentrations above 10<sup>-3</sup>.</p></figure>
Revision as of 13:50, 1 November 2017
Introduction
As part of the EncaBcillus project, we developed a novel and complete heterologous biosensor for β-lactam antibiotics in Bacillus subtilis. This biosensor is based on a one-component system encoded in the so-called bla-operon naturally found in Staphylococcus aureus. The biosensor is composed of three composites from this operon: The β-lactam receptor BlaR1 receptor and the repressor BlaI which have been codon-adapted for expression in B. subtilis as well as the PblaZ promoter [BBa_K2273111](see Figure 2). This promoter was inserted upstream of the lux-operon, our reporter of choice. Figure 1 displays the molecular mechanism of the established biosensor. In case a β-lactam is bound to BlaR1, the receptor`s proteolytic c-terminal domain degrades the BlaI repressor, thereby releasing the PblaZ promoter. This enables binding of the transcription machinery to the promoter and therefore the expression of the luxABCDE genes, resulting in a luminescence signal produced by the bisosensor.
This biosensor project turned out to be successful as our biosensor showed a great performance in all conducted experiments. For this reason, we created this section to apply for “best basic part” with the PblaZ promoter [BBa_K2273111]. As this promoter showed high activity and reliability when induced by β-lactams, a clear differentiation between background and the desired signal was possible. The results demonstrated in the paragraphs below, validate the functionality of the biosensor and thus also the functionality of its composites.
Proving the functionality of PblaZ
1. Assessing the activity of PblaZ in liquid medium
Summary
Taking together all the results obtained in this project, we can conclude that all three biosensors show excellent functionality under various different conditions. All strains are able to detect the six β-lactams, though the biosensors 2 and 3 perform better on solid MH-medium. Generally speaking, the PblaZ promoter, as part of the biosensor strains, generates a high luminescence signal that can be easily detected in liquid and on solid media. Further, our results show high reproducibility of the strong promoter activity in the conducted experiments evaluated in the section above.
Another potential application for the PblaZ promoter other than in the context of a biosensor would be in the framework of an expression system. As already very low concentrations of e.g. cefoperazone are leading to strong activation of the promoter by the BlaR1-BlaI system, you could think of replacing the lux-operon by any gene of interest. This promoter reached even higher activities than the constitutive promoter Pveg. For this reason, we also propose this system for the overexpression of proteins of interest.