Team:Glasgow/Hardware

Glasgow iGEM 2017
Hardware


Overview

The aim of our work is to develop a low-cost device to introduce the sample, extract the biomarker, xylulose, and house the <a href="https://2017.igem.org/Team:Glasgow/mtlR">biosensing bacteria</a>, all in a self-contained device.

Xylulose extraction has been carried out previously in “Structural Analysis of the Capsular Polysaccharide from Campylobacter jejuni” (Gilbert et al., 2007) [1] using the fact that it is very acid labile. The process involved heating the sample with acetic acid to a temperature of 100°C. To enable the device to be portable and used in the field, we targeted the use of microfluidics techniques to extract and detect xylulose.

The device consists of 3 elements (as shown in figures X, Y and Z):

  1. A swab, used to gather the sample from the environment, attached to a syringe containing 1% acetic acid in tris acetate (TAE) buffer.
  2. A self-contained (to avoid contamination) combined processing plate and heating circuit for preparing the sample for detection.
  3. A Device casing to house and contain the processing plate and electronics

The processing plate contained a section to house the <a href="https://2017.igem.org/Team:Glasgow/mtlR">genetically modified bacteria</a> that has been developed for our project, and allow the user to observe if there was any Campylobacter present in the original sample.

One part that is not available in this design is the detection system. In this version, we rely on eye inspection, but this could be implemented in a quantifiable system using for example a smartphone.


Challenges

  1. Neutralisation: Using acid for the extraction of xylulose would be detrimental to our biosensor down the line, killing our biosensing E.Coli. We thus have to neutralise the acid using an equivalent alkali. We also integrate a measurement of the pH to validate that the process is not harmful to our biosensor.
  2. Hierarchical Metabolism: Bacteria are able to metabolise xylulose [ref], which means that our biosensor carries the risk of not producing the reporter molecule upon addition of xylulose. We thus chose to add glucose to the sample before the contact with the biosensor, as E.Coli will metabolise glucose first, while xylulose is used by the biosensing pathway.
  3. Gel Encapsulation: Biosensor storage in the device. Our device is targeted at Point-of-need application and thus requires to be portable and to have all reagents already stored within the device.
  4. Heater Circuit: In order to carry out the heating step of the procedure, it was necessary to raise the temperature to 100°C. In light of this, a heater circuit was designed.


Materials and Methods

Condition set up

Sample preparation

  • 1
  • 2
  • 3

Glasgow2017 caption image1.JPG
Table 1: Optical density analysis of S. thermophilus growth


Results and Discussion

Outlook

References

  1. Gilbert, M., Mandrell, R., Parker, C., Li, J. and Vinogradov, E. (2007). Structural Analysis of the Capsular Polysaccharide fromCampylobacter jejuni RM1221. ChemBioChem, 8(6), pp.625-631.

Using synthetic biology to create a biosensor for detection of Campylobacter jejuni, a bacteria linked to food poisoning.