Contents
Context
Campylobacter jejuni is a Gram-negative, microaerophilic, corkscrew-shaped bacteria which has been implicated in as being one of the most common causes of human gastroenteritis worldwide. WHO estimates that 1 in 10 people around the world fall ill with a Campylobacter infection annually.[1] Infection with this bacteria in the UK was recently estimated to cost health services £50 million (in 2008-2009 prices), with a cost of £85 per case.[2]
Infection with Campylobacter causes common symptoms such as diarrhoea, abdominal pain, fever, headache, nausea and vomiting. [1] C. jejuni grows optimally between 37 and 42 degrees C and is most commonly found on undercooked poultry, though it has been reported in other undercooked meat and meat products, raw milk, and in untreated drinking water [1]. The high prevalence of C. jejuni makes it a key target for synthetic biology-based solutions.
Treatment and Prevention
Treatment for Campylobacteriosis (Campylobacter-caused diarrhoeal disease) is generally only given in the most severe cases or when patients are vulnerable, and usually consists of giving more fluids and glucose-electrolyte solutions to ensure dehydration does not occur. [3] Erythromycin therapy can also be given but little clinical benefit is seen if the treatment is begun after four days of symptom onset. [4] However, the use of antibiotics can be recommended in the case of patients who are immunocompromised, pregnant, or with very severe symptoms.[3]
Prevention of this infection is very easy, with several strategies from the farm to the consumer recommended by WHO: [1]
- Enhanced biosecurity to avoid transmission of Campylobacter from the environment to the flock of birds – only in closed housing conditions
- Good hygienic slaughtering practices carried out
- Prevention methods in domestic kitchens are similar to those specified for other foodborne bacterial infections – ensure meat is cooked through and that milk has been pasteurized before consumption
Current Detection Methods
Culture based screening methods
Traditional methods for detection of Campylobacter include culturing a swabbed sample on selective media and incubating for 48 hours at 42degreesC under microaerobic conditions. After isolating the bacteria in this way, identification through looking at the morphology and overall characteristics of the bacteria is carried out. Culture-based methods are relatively cheap to carry out and require less training than others techniques, but are incredibly time and labour intensive and therefore, in recent years, a move has been made towards use of rapid detection testing. [5]
Rapid detection methods
More recently, techniques such as enzyme immunoassay and lateral flow systems have been utilised to test for Campylobacter, as they require only between one and two hours until a result is given. [6] However, use of these methods required much more highly trained employees to carry them out, and so therefore detection of Campylobacter in an industrial or agricultural setting would most likely have to be outsourced to a company specialising in these services. A particular study doing a comparison into three rapid detection systems showed a high number of false negative results, which can be considered an additional drawback when looking at detection of C. jejuni in order to reduce the incidence of disease outbreaks. [7]
Our device
In an attempt to reduce incidences of food poisoning by Campylobacter jejuni we decided to create a biosensor that was able to detect the presence of Campylobacter jejuni quickly and accurately. To do this we aimed to create a two part biosensor that will detect both xylulose – a rare sugar that is present of the Campylobacter jejuni capsule – and autoinducer-2, a quorum sensing molecule used by campylobacter. For the detection of xylulose two possible avenues were explored: utilising the mannitol operon, that is known to detect xylulose but may have some off target affects; and mutagenesis of the arabinose operon with an aim to change its target sugar to xylulose. The detectors for both xylulose and autoinducer-2 will form the two components of an AND gate that will ensure only a signal is seen when both xylulose and untoinducer-2 are present. Regarding the application of our biosensor we designed a device that would house the biosensor to make the application simple and easy. In addition to this we also looked at producing xylulose in a cheap and efficient way as the cost of xylulose held us back with regards to thorough testing of the biosensor elements. All of the above were done with thought of the implications with regards to human practices and how a genetically engineered biosensor would be received by the public.
- Why xylulose/why autoinducer-2?
References
- ↑ 1.0 1.1 1.2 1.3 http://www.who.int/mediacentre/factsheets/fs255/en/
- ↑ Tam CC, O’Brien SJ (2016) Economic Cost of Campylobacter, Norovirus and Rotavirus Disease in the United Kingdom. PLoS ONE11(2): e0138526. https://doi.org/10.1371/journal.pone.0138526
- ↑ 3.0 3.1 https://emedicine.medscape.com/article/213720-treatment
- ↑ https://emedicine.medscape.com/article/176400-overview
- ↑ http://www.rapidmicrobiology.com/test-method/campylobacter-detection-and-identification-methods/
- ↑ Giltner CL, Saeki S, Bobenchik AM, Humphries RM. Rapid Detection of Campylobacter Antigen by Enzyme Immunoassay Leads to Increased Positivity Rates. Journal of Clinical Microbiology. 2013;51(2):618-620. doi:10.1128/JCM.02565-12.
- ↑ Granato PA, Chen L, Holiday I, et al. Comparison of Premier CAMPY Enzyme Immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY Tests with Culture for Laboratory Diagnosis of Campylobacter Enteric Infections . Journal of Clinical Microbiology. 2010;48(11):4022-4027. doi:10.1128/JCM.00486-10.